EasyManua.ls Logo

Denon DCD-1420 - Special Test Modes; Heat Run Mode Operation; Chucking and Skipping Tests

Denon DCD-1420
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ca
ee
nn
ee
on
ees
HEAT
RUN
MODE
FUNCTION
1.
Heat
Run
Mode
1)
To
active
Push
and
hold
1,
4,
and
7
keys
simultaneously,
and
turn
power
on.
The
remote
control
sensor
indicator
lights
to
show
that
the
unit
is
shifted
to
Heat
Run
Mode.
Be
sure
the
disc
has
been
loaded.
Press
the
disc
holder
open/close
button
(4£OPEN/CLOSE)
to
cancel
Heat
Run
Mode.
2)
Operation
Shifting
the
unit
to
Play
Mode
from
Heat
Run
Mode
makes
the
unit
replays
from
the
first
music,
by
opening
the
loader
once
and
re-closes
it
when
finish
playing
the
last
music
(comes
into
lead
out).
Hereafter,
operates
open/close
of
loader,
servo
on,
reads
TOC,
and
repeats
playing
the
two
music
the
first
and
last
ones.
If
a
system
error
occurs
during
Heat
Run
Mode,
it
displays
the
error
message
TNO
on
the
INDEX,
and
stops
the
operation.
And
displays
the
previous
operation
cycle
number
on
TIME.
1.
E1
When
focus
servo
is
ineffective:
1-1
E1-00
No
FOK
avails.
1-2
E1-01
FOK
avails
but
no
FZC.
1-3
E1-02
Both
FOK
and
FZC
avail,
but
FZC
is
short
of
masking
time.
1-4
E1-03
Both
FOK
and
FZC
avail,
but
FZC
did
not
turn
to
“L”
within
specified
time.
2.
E2
Disc
turns,
but
fails
to
detect
synchronous
pattern
(No
GFS).
3.
E3
Fails
to
detect
synchronous
pattern
(No
GFS
drives.):
3-1
E3-00
During
PLAY.
3-2
E3-01
During
SEARCH.
4.
E4
Servo
avails,
but
fails
to
read
TOC:
4-1
£4-00
Fails
to
read
subcode.
4-2
E4-01
Reads
subcode,
but
fails
to
lead-in.
4-3
E4-02
Subcode
and
lead-in
avail,
but
fails
to
read
TOC
within
15s.
5.
Ed5
Defective
loader.
(Switch
fails
to
turn
on.)
6.
E6
PU
innermost
circle
switch
fails
to
turn
off.
7.
E7
PU
innermost
circle
switch
fails
to
turn
on.
2.
Chucking
Test
1)
To
activate
Start
regular
Heat
Run
Mode,
and
press
1
(PAUSE)
twice
times,
or
10
key.
(During
PLAY)
2)
Operation
Repeats
Close/Open
loader,
Servo
on,
reads
TOC,
selection
of
the
first
music.
3)
Error
Message
The
same
as
per
regular
Heat
Run
Mode.
Always
displays
number
of
operation
cycle
on
TIME,
immediately
after
the
loader
closes.
3.
Sound
Skipping
Test
1)
To
activate
Start
regular
Heat
Run
Mode,
and
press
+10
key.
(During
PLAY)
2)
Operation
If
sound
skipping
occurs
more
than
+8
frame
(no
continuous
subcode),
it
stops
the
operation,
and
displays
error
message.
3)
Error
Message
E8
Sound
skipping
occurs.
Displays
number
of
operation
cycle
on
TIME.
Then,
if
press
any
key,
display
changes,
and
displays
the
section
where
skipping
occurs
on
TNO
INDEX
TIME.
Pan
PD
One
we
Be
en
mln
Lianne
Disn
Mada

Related product manuals