The following transition occurs during an update. The same occurs in network and USB updates.
The network connection is
complete
FIRMWARE UPDATE PROCE-
DURE
Rebooting
Setting complete
Network connection com-
plete
Blue : SolidAmber : BlinkingBlue : Slow BlinkingBlue : Solid
Amber blinking = About 250ms On/Off
The following transition occurs during a Service Region Settings update.
Connect USBChange regionChange completeEND
Blue : SolidGreen : BlinkingBlue : Blinking(X times)Blue : Solid(7sec.)
X=The indicator blinks the same number of times as the region number being set. (North America=1, Europe=2, Japan=3, Australia=4,
Korea=5)
The following transition occurs during a service release type update.
Connect USBChange release typeChange completeEND
Blue : SolidGreen : BlinkingBlue : Blinking (3 time)Blue : Solid (7sec.)
The following transition occurs on startup.
Power offStartingSetting complete
Connected to network
Led : OffBlue : BlinkingBlue : Solid
Setup not completed
Refer to "QSG".
Set up the network connec-
tion
Amber : Solid
1. Updating
2. Updating (Service region settings)
3. Updating (Service Release Type)
4. On startup of HEOS (when power is turned on)
Press and hold the "
Bluetooth
" button before inserting the power plug, then insert the power plug
while holding down the button and wait for more than 5 seconds.
Network connectedResetting to factory defaultStartingNot set up
Blue : SolidAmber : BlinkingBlue : Blinking
Amber : Solid
(Blinking -> lit)
*Blue indicator blinks mo-
mentary during the process
Amber Blinking = About 750ms On/Off : About 130sec
Press and hold the "
Bluetooth
" and "
Connect
" buttons for 5 seconds or more while connected to the
network.
Network connectedSoft reset startStartingNot set up
Blue : SolidAmber : Fast BlinkingBlue : Blinking
Amber : Solid
(Blinking -> lit)
Amber Blinking = About 250ms On/Off : About 25sec
The following transition occurs on startup.
Power offStartingCritical Error
Firmware Error
Led : OffBlue : Slow BlinkingRed : Slow Blinking
Critical Error
Hardware Error
Red : Fast Blinking
Slow Blinking : 750ms On/Off, Fast Blinking : 250ms On/Off
5. Factory Reset
6. Software Reset (Clear user settings)
7. Critical Error
Status LED Connect in Status LED
LED STATUS