Please read this USER’S MANUAL before operating this equipment.
Global TOP 10 in Healthcare
LUVIS L200 USER’S MANUAL
(V2.2) Mar/12/2018
Major Surgical Luminaire
DENTIS CO., LTD.
99, Seongseoseo-ro, Dalseo-gu, Daegu, Korea
Tel. 82-53-583-2804 FAX. 82-53-583-2806 www.dentis.co.kr / www.luvis.co.kr

Questions and Answers

  • A
    Arthur WardAug 10, 2025
    What to do if the LED light on the DENTIS LUVIS L200 LIGHTHEAD does not turn on?
    • W
      William LeeAug 10, 2025
      If the LED light on the LIGHTHEAD doesn't turn on, first check if the supply mains are operating. If the issue isn't power, and you have a backup power supply (UPS), contact your supplier. Otherwise, press the stand-by button on the control panel to see if the LED turns on. If the green light still doesn't illuminate, do not attempt a repair; contact your supplier.
  • O
    ofloydAug 15, 2025
    What to do if the SAFETY COVER of the DENTIS LUVIS L200 Medical Equipment LIGHTHEAD is polluted?
    • M
      Mrs. Natalie Collier PhDAug 15, 2025
      If the SAFETY COVER of the LIGHTHEAD is polluted, cleanse it with designated chemicals such as Alcohol or Ethanol. If, after cleaning, the essential performances of the device, like Intensity of Illumination or Color Temperature, are seriously impaired, please contact your supplier.
  • J
    Julia NguyenAug 20, 2025
    Why LIGHTHEAD is not fixed after handling and moves left and right in DENTIS LUVIS L200 Medical Equipment?
    • A
      Andrew PetersAug 20, 2025
      If the LIGHTHEAD moves left and right after handling, it may be due to an incorrectly adjusted BRAKE SCREW. Check the verticality and horizontality of the installed device using a circular leveler. Use a flat-head screwdriver to tighten the BRAKE SCREWs as shown in the picture. If the condition does not improve, do not attempt to repair; contact your supplier.
  • S
    stevenwongAug 25, 2025
    What to do if there is an error in the light pattern formation of DENTIS Medical Equipment?
    • C
      Christopher HernandezAug 25, 2025
      If there is an error in the light pattern formation, check if the distance between the LIGHTHEAD and the bed is the recommended 1 meter. If the condition does not improve, do not attempt to repair; please contact your supplier.
  • G
    Glenda PierceAug 29, 2025
    What to do if normal power supply, but the power of the camera does not increase in DENTIS LUVIS L200?
    • K
      Katelyn CastilloAug 29, 2025
      If the power supply is normal, but the camera power does not increase, it could be due to a wrong connection of the power supply line (Power supply, Lighthead power). Please contact your supplier.
  • J
    jamesninaSep 4, 2025
    What to do if it is not output video from DENTIS LUVIS L200 Medical Equipment?
    • S
      Sarah CollinsSep 4, 2025
      If there is no video output, the issue might be with the video cable or HD-SDI convertor. Check the video cable. Please contact your supplier.