Explains the Cavitron Built-In Ultrasonic Scaler and its Sustained Performance System (SPS) for balancing efficiency and comfort.
Details how the system converts SELV source current to high frequency current for ultrasonic scaling.
All general supra and subgingival scaling applications. Periodontal debridement for all types of periodontal diseases.
Not for restorative procedures involving amalgam condensation. Not for use on children under age 3.
Caution for patients with implanted medical devices regarding potential electronic interference.
Dental professional's duty to determine appropriate product uses and understand patient health.
Covers anti-retraction features, sterile kit use, boil-water advisories, and environmental conditions.
Addresses proper insert handling, sterilization processes, and mounting location warnings.
Emphasizes equipment flushing, dental water supply maintenance, and proper handpiece seating.
Covers operating without fluid, electrical connections, using Cavitron system components, and insert wear.
Details retracting lips/cheeks, using water, adjusting power, and universal precautions.
Stresses practicing infection control procedures and managing aerosols produced by the scaler.
Advises conforming to CDC/ADA standards and following guidelines for water quality.
Specifies incoming water pressure limits and maximum temperature for the scaler.
Details installation of shut-off valves, filters, and flushing procedures for the water supply line.
Explains how the module is enabled, ON/OFF function via foot control, and power adjustment options.
Describes how to adjust water flow through the handpiece using a control element on the cable.
Details which Cavitron 30K inserts are compatible with the Steri-Mate handpiece.
Explains how to rotate the handpiece nose for adjustable hand positioning and access.
How to adjust lavage by twisting the blue knob clockwise to control flow rate and temperature.
Describes the O-Ring, Connecting Body, Insert Tip, Finger Grip, Insert Marking, and Magnetostrictive Stack.
Instructions on lubricating the O-Ring and seating the insert into the handpiece.
Guides on adjusting the chair, patient head position, and chin angle for optimal access.
Covers retracting tissues, using adequate lavage, and applying a light touch for effective scaling.
Lists causes of sensitivity like incorrect tip placement, static position, and applying too much pressure.
Step-by-step procedures for starting the system daily, including handpiece and insert preparation.
Steps for cleaning and sterilizing handpiece, inserts, and cable assembly between patient treatments.
Procedures for flushing the system, cleaning/disinfecting components, and powering down at end of day.
Addresses issues like low vibrations, power settings, and checking insert wear.
Guides on checking scaler energization, handpiece connection, and insert status for no water flow.
Troubleshooting steps for no vibrations when water is flowing, including power and insert checks.
Addresses scaler handpiece getting too hot, output water temperature, and related adjustments.
Details the warranty duration for the Cavitron Built-In Scaler and Steri-Mate Handpiece.
Lists operating conditions, power, water flow, storage, and atmospheric pressure specifications.
Details electrical shock protection, ingress protection, mode of operation, and medical device classification.
Explains symbols for Type B Equipment, Consult Instructions For Use, and AC power.
Details compliance with UL, CSA, and CE standards for medical equipment safety.