ENGLISH 1
Cavitron
®
Built-In
G139
Directions For Use
Ultrasonic Scaler with
Cavitron
®
Steri-Mate
®
Handpiece
Model
Question and Answer IconNeed help?

Do you have a question about the DENTSPLY Cavitron G139 and is the answer not in the manual?

DENTSPLY Cavitron G139 Specifications

General IconGeneral
BrandDENTSPLY
ModelCavitron G139
CategoryMedia Converter
LanguageEnglish

Summary

Introduction to Cavitron Built-In Ultrasonic Scaler

System Overview and Performance

Explains the Cavitron Built-In Ultrasonic Scaler and its Sustained Performance System (SPS) for balancing efficiency and comfort.

System Operation Principles

Details how the system converts SELV source current to high frequency current for ultrasonic scaling.

Indications and Contraindications

Indications for Use

All general supra and subgingival scaling applications. Periodontal debridement for all types of periodontal diseases.

Contraindications for Use

Not for restorative procedures involving amalgam condensation. Not for use on children under age 3.

Important Warnings and Precautions

Pacemaker Interference Warning

Caution for patients with implanted medical devices regarding potential electronic interference.

Professional Responsibility

Dental professional's duty to determine appropriate product uses and understand patient health.

System Operation Safety

Covers anti-retraction features, sterile kit use, boil-water advisories, and environmental conditions.

Handling and Sterilization Safety

Addresses proper insert handling, sterilization processes, and mounting location warnings.

Precautions for Use

System Maintenance Precautions

Emphasizes equipment flushing, dental water supply maintenance, and proper handpiece seating.

Usage Precautions

Covers operating without fluid, electrical connections, using Cavitron system components, and insert wear.

Patient Contact Precautions

Details retracting lips/cheeks, using water, adjusting power, and universal precautions.

Infection Control and Water Lines

Infection Control Guidelines

Stresses practicing infection control procedures and managing aerosols produced by the scaler.

Water Supply Recommendations

Advises conforming to CDC/ADA standards and following guidelines for water quality.

Water Line Requirements

Specifies incoming water pressure limits and maximum temperature for the scaler.

Water Supply System Setup

Details installation of shut-off valves, filters, and flushing procedures for the water supply line.

Ultrasonic Scaler System Description

System Controls Overview

Explains how the module is enabled, ON/OFF function via foot control, and power adjustment options.

Lavage Flow Adjustment

Describes how to adjust water flow through the handpiece using a control element on the cable.

Steri-Mate® Handpiece Details

Handpiece Compatibility

Details which Cavitron 30K inserts are compatible with the Steri-Mate handpiece.

360 Rotating Handpiece Nose

Explains how to rotate the handpiece nose for adjustable hand positioning and access.

Lavage Flow Adjustment

How to adjust lavage by twisting the blue knob clockwise to control flow rate and temperature.

Cavitron® 30K Ultrasonic Inserts

Insert Components Description

Describes the O-Ring, Connecting Body, Insert Tip, Finger Grip, Insert Marking, and Magnetostrictive Stack.

Insert Installation Procedure

Instructions on lubricating the O-Ring and seating the insert into the handpiece.

Techniques for Use

Patient Positioning for Access

Guides on adjusting the chair, patient head position, and chin angle for optimal access.

Performing Scaling Procedures

Covers retracting tissues, using adequate lavage, and applying a light touch for effective scaling.

System Care and Maintenance

Patient Comfort Considerations

Lists causes of sensitivity like incorrect tip placement, static position, and applying too much pressure.

Daily Protocol - Start-up Procedures

Step-by-step procedures for starting the system daily, including handpiece and insert preparation.

Daily Protocol - Between Patients

Steps for cleaning and sterilizing handpiece, inserts, and cable assembly between patient treatments.

Daily Protocol - Shut Down Procedures

Procedures for flushing the system, cleaning/disinfecting components, and powering down at end of day.

Troubleshooting Guide

Low Vibrations Troubleshooting

Addresses issues like low vibrations, power settings, and checking insert wear.

No Vibrations/No Water Flow

Guides on checking scaler energization, handpiece connection, and insert status for no water flow.

No Vibrations with Water Flow

Troubleshooting steps for no vibrations when water is flowing, including power and insert checks.

Overheating Issues

Addresses scaler handpiece getting too hot, output water temperature, and related adjustments.

Specifications and Warranty

Warranty Period

Details the warranty duration for the Cavitron Built-In Scaler and Steri-Mate Handpiece.

Technical Specifications

Lists operating conditions, power, water flow, storage, and atmospheric pressure specifications.

Classifications

Details electrical shock protection, ingress protection, mode of operation, and medical device classification.

Symbol Identification

Standard Symbols Explanation

Explains symbols for Type B Equipment, Consult Instructions For Use, and AC power.

Medical Equipment Certifications

Details compliance with UL, CSA, and CE standards for medical equipment safety.