8-3 Check/every 100 hours
(1) Clean air cleaner element
Dry dust clings on element E L E M E N T
Remove the air cleaner element and clean the element with
dry and clean compressed air.
~ Carbon and oil clings on element
Ф Use a special element cleaner detergent.
© Soak the dirty air cleaner element in a solution of water
and special element for about 15 minutes.
@ Rinse the air cleaner element using distilled water and let
it dry in a place that is exposed to wind.
* While it is being cleaned, check the element for any
damage. Replace if necessary.
* Before installing the air cleaner, wipe off dirt on the
element cover.
* When insert the element, insert the element completely
pressing equal edge of element.
Parts number of air cleaner cartridge:
Model name Parts number Parts number of
manufacture
DCA13,15LSK Y06020 46335 11304-3002
(2) Check fan belt
Refer to the instruction manual for the engine furnished
separately.
(3) Replace engine oil
Refer to ГS-2.(l) Replacement of engine oil Seep.39J .
(4) Clean fuel filter element.
Ф Turn the fuel filter cock to the close position. Remove
the ring screw and take out the filter cup and element.
Ф Rinse the element using diesel fuel and also, clean the
inside of the filter cup using diesel fuel.
© After leaning, fit the fuel filter back to its original
position. Make sure when the fuel filter is being refitted
that it is not overly dusty.
40