(8) In the same procedure as the above items (5),(6)
and (7), parallel the generating sets of No.3 and so
on if any.
(9) Turn on the breakers on the load side. If each AC
ammeters show an imbalance in loading, make it in
equal loading by adjusting the throttle lever for engine
rpm. The set is to undertake more load sharing when
the engine rpm. is adjusted higher, while less sharing
when adjusted lower.
[Note]
AC ammeter indicates the current including a cross
current. Watt meter (Option) is required to know the
correct load sharing.