(5) Check on battery specific gravity.
If battery is likely to be discharged due to failure in startup of the engine, measure the
specific gravity of battery acid.
The relation between battery charge condition (charging rate) and specific gravity is as
shown below.
Liquid
Chargin^<temp.
rate (%)
2 0
0
- 1 0
1 0 0
1.28 1.29
1.30
9 0
1.26 1.27
1.28
8 0
1.24 1.25
1,26
7 5
1.23 1.24
1.25
Each value has a deviation of + 0.01.
When the charging rate is below 75%, the battery needs to be recharged.
Г 8 1. Caution on battery charge See p.58 j
(6) Replacement of fuel filter cartridge
Replace the fuel filter cartridge at only first 250hours.
r 9-3.(1) Replacement of fuel filter cartridge See p.69 j