(2) Cleaning of radiator
When the fin or tube is blinded, it
should be cleaned with steam or
high pressure water.
[Note]
When a high pressure washer is used, spray water from
over 1.5m
a place about 1,5m away to prevent damage to the fin or tube.
(3) Checking for terminal and connection of the circuit.
Check for main and sub circuit, whether there are no abnormality such as loosening,
corrosion and burning, etc.
(4) Checking on generator bearing
Check and supply the grease of bearing. About 1/3 of bearing chamber volume is proper
for grease quantity.
If thermo label changes color to black showing high temperature, replace the bearing.