A CAUTION
* Do not start the engine when the machine and the load circuit breaker are ON, or
else, power is supplied to the load at the start of the engine which causes electric
shocks or trouble in the load.
Startup procedure:
(1) Make sure that the circuit breakers of
the machine and the loads are all OFF.
(2) Set the throttle lever in the "START /
IDLING" position.
(3) Turn the starter switch to "START"
position after the going OFF of the
preheat lamp at the "RUN" position
of the starter switch.
[Note]
If the engine is warm, the preheat
operation is not required.
The duration of preheating differs
according to the temperature of
cooling water. And if the temperature
of cooling water is high enough, the
preheat lamp does not light because
no preheating is required.
- 43 -