8-3 Checking/every 250 hours
(1) Replacement of engine oil
Replacement is refer to Г8-2.(l) Replacement of engine oil J .
(2) Cleaning of air cleaner element
This element should be cleaned, regardless
of operating time, when the warning lamp of
"Air filter blinding" goes on.
- Diy dust clings on element -
Remove the air cleaner element and clean
the element with dry and clean compressed
air.
* While it is being cleaned, check the element
for any damage. Replace if necessary.
* Before installing the air cleaner, wipe off dirt
on the element cover.
* When insert the element, insert the element
completely pressing equal edge of element.