www.desatech.com
113900-01D 3
You must operate this replace
with the provided replace screen
(closed), hood and brick liner in
place. Make sure these parts are
in place before runningrebox.
Keep the rebox area clear and
free from combustible materials,
gasoline and other ammable
vapors and liquids.
1. This rebox shall not be installed in a
bedroom or bathroom.
2. Neverinstalltherebox
in a recreational vehicle
where curtains, furniture, clothing or
other ammable objects are less than
36" from the front and 42" from the top.
For side clearances see Figure 6 on
page 8
•inhightrafcareas
in windy or drafty areas
3. Donotusethisreboxasawood-burning
replace.Useonlydecorativeunvented
room heaters (log sets).
4. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting.
5. Vent-free gas log heaters installed in these
reboxes require fresh air ventilation to
run properly. See Air for Combustion and
Ventilation, page 4.
6. Donotrunrebox
•whereammableliquidsorvaporsare
used or stored
under dusty conditions
7. Do not use this rebox to cook food or
burnpaperorotherobjects.
8. Turnreboxoffandletcoolbeforeservic-
ing.Onlyaqualiedservicepersonshould
serviceandrepairrebox.
9. Operatingvent-freelogsetsinarebox
above elevations of 4,500 feet could
cause pilot outage.
10.Donotusethereboxifithasbeenun-
der water due to the shock hazard that
could result with the blower accessary (if
installed) in place.
11.Provideadequateclearancesaroundair
openings.
SAFETY INFORMATION
Continued
LOCAL CODES
Installandusereplacewithcare.Followall
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
State of Massachusetts: The installa-
tion must be made by a licensed plumber
or gas tter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-red supplemental room heaters
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in
the Commonwealth of Massachusetts.
UNPACKING
1. With utility knife, cut the carton all the way
around above the staples on the bottom
tray.Liftthecartonofftherebox.Remove
packing.
2. Check carton contents for the following:
Screen assembly
Screen support rod
Hardware and parts bag containing the
following:
Owners Operation and Installation
Manual
Black #10 x 3/8" Phillips screws
3. If any items are missing, inform dealer
whereyouboughttherebox.
4. Check all items for any shipping damage.
If damaged, promptly inform dealer where
youboughtrebox.