www.desatech.com
113900-01D 7
WARNING: Never install the
rebox
in a bedroom or bathroom
in a recreational vehicle
where curtains, furniture,
clothing or other ammable
objects are less than 36" from
the front and 42" from the top
of rebox - for side clearances
see Figure 6, page 8
in high trafc areas
IMPORTANT: Vent-free gas log heaters add
moisturetotheair.Althoughthisisbenecial,
installing rebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See Air for Combustion
and Ventilation, page 4.
IMPORTANT:Makesurethereboxislevel.
If rebox is not level, log set will not work
properly.
Note:Yourreboxisdesignedtobeusedin
zero clearance installations. Wall or framing
material can be placed directly against any
exterior surface on the rear, sides or top of
yourrebox,exceptwherestandoffspacers
are integrally attached. If standoff spacers
areattached toyourrebox,thesespacers
can be placed directly against wall or fram-
ing materials.
Use the dimensions shown for rough openings
to create the easiest installation (see Built-In
Firebox Installation, page 12).
Ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling
andonewithin12"oftheoor.Connectthese
items directly to the outdoors or spaces open
to the outdoors. These spaces include attics
and crawl spaces. Follow the National Fuel
Gas Code ANSI Z223.1/NFPA 54, Section 5.3,
Air for Combustion and Ventilationforrequired
size of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.
Figure 5 - Ventilation Air from Outdoors
Outlet
Air
Ventilated
Attic
Outlet
A
ir
Inlet
Air
Inlet Air
Ventilated
Crawl Space
To
Crawl
Space
To Attic
INSTALLATION
NOTICE: This heater is intended
for use as supplemental heat.
Use this heater along with your
primary heating system. Do not
install this heater as your pri-
mary heat source. If you have a
central heating system, you may
run system’s circulating blower
while using heater. This will help
circulate the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.
WARNING: A qualied ser-
vice person must install rebox.
Follow all local codes.
AIR FOR COMBUSTION
AND VENTILATION
Continued