4. Open propane supply valve on propane
tank(s) slowly. Note: If not opened slowly,
excess-ow check valve on propane tank
may stop gas ow. If this happens, you
may hear a click inside the regulator as-
sembly, this is the check valve closing. To
reset the excess ow check valve, close
propane supply valve and open again
slowly.
5. Slightly press and turn control knob
counterclockwise to the LO position (see
Figure 5).
6. With the control knob pushed all the way
in, press and release the piezo ignitor
button. Keep pressing piezo ignitor but-
ton until the burner lights. Hold control
knob down for a maximum of 15 seconds
while attempting ignition. If heater does
not ignite, release control knob and wait
3 minutes before attempting to reignite.
7. After ignition, hold control knob down
for about 30 seconds. This activates the
automatic control system.
8. When burner remains lit, set heater at the
desired heat level by slightly depressing
the control knob and turning it counter-
clockwise to the MED or HI settings (see
Figure 5, page 5).
9. If burner goes out, turn off gas. Slightly de-
press and turn control knob fully clockwise
to OFF. Check fuel supply. If adequate
fuel is available, restart heater beginning
at step 1, page 5.
CAUTION: Always run heater
with control knob at LO, MED or
HI settings. Never set control
knob between OFF, LO, MED or
HI settings.
TO STOP HEATER
1. Tightly close propane supply valve on
propane tank(s). Allow heater to burn
remaining fuel in hose.
2. Shut off burner. Do this by pushing in the
control knob and turning clockwise to the
OFF position.
TO RESTART HEATER
1. Wait ve minutes after stopping heater.
2. Restart heater by following To Start
Heater, page 5.
OPERATION
Continued
200,000 BTU/HR HEATER
TO START HEATER
1. Before lighting pilot fully close the ball
valve (turn knob fully clockwise).
2. Fully open the valve on the propane
cylinder and wait 15 seconds before
proceeding to step 3.
3. Press red button on safety pilot valve
admitting gas to the heater. Then push
and release the ignitor button until the
pilot lights.
4. When the pilot lights, continue to hold the
button depressed for 30 seconds, then
release.
5. If pilot goes out, wait 5 minutes and repeat
the lighting procedure.
6. When the pilot remains lit, open the ball
valve (turn knob counterclockwise) to
light main burner. Partially close valve to
regulate heat output.
Figure 6 - Starting Heater
Ignitor
Button
Ball Valve Control
Knob Button
TO STOP HEATER
1. Securely close valve on the propane
cylinder.
2. Continue to operate heater until all fuel in
the hose has burned.
3. Fully close the ball valve.
TO RESTART HEATER
1. Securely close valve at propane cylinder.
2. Wait 5 minutes.
3. Restart heater by following To Start
Heater.
Safety Pilot
Valve