DUO-60 v2.3 (01/2021) Page 4
List of Components
Hull Valve
Ø Must be placed as low as possible in the boat so as to avoid drawing in
any air
Ø Must be installed towards the back for a motorboat, or centered near the
keel for a sailboat. The ribs of the strainer should be placed towards the
front the boat to force the entry of water by scooping during navigation.
Ø The strainer of the hull valve helps stop large particles at the
entrance of the system.
Prefilter
Ø Must be placed as close as possible to the hull valve and, if
possible, beneath the waterline to ensure a better yield/output. If
this is not possible, you must install a pre-pump (optional).
Ø Helps stop solid particles in seawater at the inlet of the
motor/pump block. Up to 5 microns.
Ø Comes with a tool for screwing / unscrewing the tank.
Ø Comes equipped with a solenoid valve for automated rinsing.
Ø Comes equipped with a 3-way valve.
Front Control Panel
Composed of the following elements:
Ø A high-pressure manometer
Ø A flowmeter
Ø A start switch
Ø A know for pressure adjustment
Ø An operating hours counter
Ø Three indicator lights