Overview of the Eagle Quantum System's roles in monitoring and protecting hazardous areas.
Key capabilities and specifications of the Eagle Quantum System, including release capabilities and network support.
Explains how system nodes monitor inputs, process alarms, and communicate within the network.
Details the system's technique for detecting and isolating wiring faults to maintain communication.
Explains the Logic Controller's role in executing fire suppression logic and managing system operations.
Details the Communication Gateway's function in system configuration, monitoring, and external interfaces.
Describes the Isolation Module's function in protecting network wiring and providing serial port isolation.
Explains the function of the key switch in selecting operating modes for the Logic Controller.
Lists features of the Isolation Module, including ground fault detection and RS-232 isolation.
Explains the Isolation Module's role in protecting network integrity and providing serial port isolation.
Outlines features of power supplies and monitor, including output ratings and fault isolation.
Explains the EQ2100PSM monitor's role in system power status reporting.
Lists Relay Module features like programmable relays and SPDT dry contacts.
Outlines Release Module features for signaling and agent release capability.
Lists Signal Audible Module features for controlling audible/visual appliances.
Describes EQ2200IDC series IDC models and their input/output capabilities.
Describes the EQ2200UV UV Flame Detector, including sensor and control circuitry.
Describes the EQ2200UVHT UV Flame Detector for high-temperature applications.
Explains the EQ2200UVIR Flame Detector's design to prevent false alarms using combined UV and IR sensors.
Explains how operating mode determines fire signal processing logic in UV flame detectors.
Details the Arc Rejection Mode for preventing nuisance alarms from electrical arcs.
Details logic choices (standard/arc rejection) for the UV portion of the UV/IR detector.
Describes DCU/DCUEX units for digitizing analog signals and transmitting via LON/SLC.
Provides instructions for assembling and wiring DCU/DCUEX units with sensors.
Explains the EQ2500ARM's function in providing agent release capability for the Eagle Quantum system.
Explains how to set the unique address for the ARM using DIP switches.
Details the EQ2500SAM's function in providing indicating circuits for audible/visual appliances.
Describes how to assign a unique address to the SAM using DIP switches.
Explains how the EQ2400NE Network Extender expands system capabilities by adding nodes and wiring.
Details system capacity limits and how network extenders increase them.
Discusses how windows affect UV detector performance by attenuating UV radiation.
Provides guidelines for correct UV detector orientation to optimize performance and avoid false alarms.
Lists UV sources that can cause false alarms, such as arc welding and lightning.
Outlines factors for determining sensor placement, including gas type and ventilation.
Warns about high gas levels affecting catalytic sensing elements and the need for recalibration.
Explains the operation principle of catalytic gas sensors using a pair of elements.
Details power wiring requirements, including voltage input and preventing voltage drop.
Explains LON/SLC wiring in a loop and specifications for communication cable.
Describes proper connection of shield ground terminals for LON/SLC wiring to prevent shorts.
Details standby current requirements for system components to calculate battery backup.
Explains how to calculate minimum backup battery size based on system load requirements.
Provides instructions for wiring the EQ2100PSM power supply monitor to the power supplies.
Details the terminal connections for the logic controller's relay contacts.
Describes power wiring connections for main and auxiliary inputs to the LIOU.
Explains assigning a unique address to each relay module using switch assemblies.
Explains assigning address and setting solenoid/initiator configuration using switches.
Describes assigning a unique address to the Signal Audible Module using DIP switches.
Describes EQ2200IDC series IDC models and their input/output capabilities.
Explains configuring the EQ2200IDCGF as an IDC and its input fault conditions.
Instruction to remove the junction box cover for the EQ2200IDCSC.
Specifies wiring requirements for UV detector, including wire gauge and cable type.
Details mounting and assembly steps for the EQ2200UVHT detector's electronic module.
Covers mounting and wiring for the EQ2200UVIR detector, including environmental considerations.
Explains connecting H2S/O2 sensors to DCU using sensor separation kits.
Provides instructions for assembling and wiring the DCU with PointWatch detectors.
Details assembly and wiring for DCUEX with combustible gas sensors.
Explains how to set the unique address for the ARM using DIP switches.
Describes how to assign a unique address to the SAM using DIP switches.
Explains assigning a unique address to the network extender using DIP switches.
Ensures junction boxes are securely mounted and detectors are correctly oriented.
Verifies proper insulation and grounding of all cable shields for safety.
Verifies accuracy of sensor and LON/SLC wiring connections.
Confirms correct power wiring installation and operational power source.
Details switch settings for gateway hardware and software serial port configurations.
Describes setting the Modbus/Allen Bradley address for Port 1 using switches.
Describes setting the LON/SLC address for Logic Controller using DIP switches.
Explains setting unique LON/SLC address for field devices using DIP switches.
Covers general pre-commissioning checks for installation, including shields and electrostatic precautions.
Details pre-commissioning checks for LON network, including address settings and voltage measurements.
Outlines LCU pre-commissioning checks, including switch positions and data download.
Covers LIOU pre-commissioning checks, including jumper and switch settings.
Guides users through programming the system using Det-Tronics software for desired operation.
Instructs to calibrate all system sensors to ensure optimal performance.
Provides steps for manual normal calibration of universal DCUs using zero and calibration gas.
Warns about de-classifying hazardous areas before removing junction box covers with power applied.
Details routine calibration steps for combustible gas DCUs, including applying zero and calibration gas.
Advises comparing part numbers for correct replacement sensor usage.
Warns about de-classifying hazardous areas before removing junction box covers with power applied during sensor replacement.
Provides steps for normal calibration of universal DCUs with O2 sensor, using clean air and calibration gas.
Details routine calibration for DCUs with PointWatch, including zero gas and calibration gas application.
Warns about de-classifying hazardous areas before removing junction box covers with power applied for sensor replacement.
Guides through testing fire alarm response of UV detectors using a UV source.
Explains false alarm tests for UV detectors and adjusting settings to mitigate issues.
Stresses disabling extinguishing equipment before testing UV/IR detectors.
Lists FMRC, CSA, CENELEC, and CE Mark certifications for the Eagle Quantum system.
Specifies input voltage range for EQ2100LCU, noting tolerance for overvoltage.
Emphasizes regular checks and calibration for reliable system protection.
Highlights necessity of regular calibration for all gas sensors, specifying frequencies.
Provides common symptoms and causes for gateway malfunctions.
Lists common symptoms and potential causes for Logic Controller issues.
Lists part numbers for the Local Control Unit and its replacement modules.
Lists part numbers for various LON devices, including detectors and communication units.
Lists part numbers for power supplies and power supply monitors used with the system.
Details FMRC approved configurations for EQ2100LCU series, including hazardous location ratings and performance criteria.
Details CSA approved configurations for EQ2100LCU series, including hazardous location classifications.
States CE compliance with EN standards for electromagnetic compatibility and immunity.
Lists CENELEC certifications for various system components, including hazardous location ratings.
Details CENELEC certifications for standard temperature UV Flame Detector, including EEx d ratings.
Provides special conditions for safe use of UV detectors, regarding hazardous areas and installation.