Questions and Answers

  • L
    Levi CoxAug 2, 2025
    What to do if my DEVI devireg 530 Thermostat has no heat?
    • R
      Ricky GarciaAug 2, 2025
      If your DEVI Thermostat isn't producing heat, start by checking the main fuse, the residual current device (RCD), and other safety devices. If those are fine, ensure all cables connected to the thermostat are properly installed. As a last resort, consider replacing the thermostat or the NTC sensor.
  • W
    wallaceteresaAug 9, 2025
    Why is my DEVI devireg 530 always on?
    • B
      Brianna JohnsonAug 9, 2025
      If your DEVI Thermostat is providing constant heat, it could be due to a relay being constantly on or a floor sensor interrupt. Try replacing the thermostat or replacing the NTC sensor.
  • A
    Amber MorrisonAug 16, 2025
    What to do if my DEVI Temperature Controller has no heat?
    • S
      Sheena BuchananAug 17, 2025
      If your DEVI Temperature Controller is not producing heat, ensure all cables connected to the thermostat are correctly connected to the appropriate terminals, and all connections are secure. Also, verify that the RCD and contactor are switched on. If these steps don't resolve the issue, measure the voltage at terminals 2 and 4 when the temperature dial is turned up and the neon indicator is red. Check the heating cable resistance with an ohmmeter and make sure there is no leakage between the conductor and earth. Measure the ohm value of the NTC sensor wire. If problems persist, the thermostat or NTC sensor may need replacement.
  • M
    Michael RyanAug 25, 2025
    Why is my DEVI Temperature Controller constantly heating?
    • G
      Gabrielle MooreAug 26, 2025
      If your DEVI Temperature Controller is constantly heating, measure the voltage at terminals 2 and 4 with the temperature turned down. Also, disconnect the external NTC sensor from terminals 5 and 6 on the thermostat. The thermostat or NTC sensor may need replacement. This issue may be caused by the relay constantly being on or a floor sensor open circuit.

Summary

1. Applications and Functions

2. Maximum floor temperature setting

3. Neon light indications (LED)

4. Installation instructions

5. Install sensor for Devireg 530 and 532

6. Placement of Devireg 530, 531, and 532

7. Connection diagrams for Devireg 530, 531, and 532

8. Trouble shooting

No light on thermostat

Troubleshooting steps for when the thermostat shows no light.

Fault: No heat

Diagnosing and resolving issues when the system is not heating.

Heating cable diagnostics

Checking resistance and insulation of the heating cable for faults.

External sensor input testing

Testing the external NTC sensor for proper resistance values.

Fault: Constant heat

Troubleshooting when the relay remains constantly on, causing continuous heating.

Floor sensor open circuit

Diagnosing issues with an open-circuited floor sensor leading to thermostat failure.

9. Technical specifications for Devireg 530, 531, and 532

Temperature range and monitoring

Details on operating temperatures, sensor failure monitoring, and LED indicator states.

IP class and dimensions

Information on the device's IP protection rating and physical size specifications.

Australian Warranty Certificate

DEVI Denmark Warranty Terms

DEVI Warranty Certificate Form

DEVI devireg 530 Specifications

General IconGeneral
TypeElectronic thermostat
Power supply230 V AC
IP ClassIP20
Accuracy± 0.5 °C
Protection classII
Operating voltage230 V
OutputRelay output
InstallationWall mounted
Max load16 A (resistive load)