  • M
    Mary SpencerAug 8, 2025
    What to do if my DEVI devireg 531 has no heat?
    • T
      Tara HoustonAug 9, 2025
      If your DEVI Thermostat isn't producing heat, start by checking the main fuse, the residual current device (RCD), and other safety devices. If those are fine, ensure all cables connected to the thermostat are properly installed. As a last resort, consider replacing the thermostat or the NTC sensor.
  • L
    Louis MillerAug 17, 2025
    Why is my DEVI devireg 531 Thermostat always on?
    • M
      Michael RomeroAug 17, 2025
      If your DEVI Thermostat is providing constant heat, it could be due to a relay being constantly on or a floor sensor interrupt. Try replacing the thermostat or replacing the NTC sensor.
  • D
    Deanna DanielsAug 23, 2025
    What to do if my DEVI Temperature Controller has no heat?
    • R
      Rebecca MullenAug 25, 2025
      If your DEVI Temperature Controller is not producing heat, ensure all cables connected to the thermostat are correctly connected to the appropriate terminals, and all connections are secure. Also, verify that the RCD and contactor are switched on. If these steps don't resolve the issue, measure the voltage at terminals 2 and 4 when the temperature dial is turned up and the neon indicator is red. Check the heating cable resistance with an ohmmeter and make sure there is no leakage between the conductor and earth. Measure the ohm value of the NTC sensor wire. If problems persist, the thermostat or NTC sensor may need replacement.
  • J
    Jennifer OnealAug 31, 2025
    Why is my DEVI Temperature Controller constantly heating?
    • M
      marquezemilySep 1, 2025
      If your DEVI Temperature Controller is constantly heating, measure the voltage at terminals 2 and 4 with the temperature turned down. Also, disconnect the external NTC sensor from terminals 5 and 6 on the thermostat. The thermostat or NTC sensor may need replacement. This issue may be caused by the relay constantly being on or a floor sensor open circuit.

Summary

Maximum floor temperature setting

Neon light indications (LED)

Installation instructions

Install sensor for Devireg 530 and 532

Floor Sensor Installation Guidelines

Details on conduit use, bending radius, placement, and extending the floor sensor cable.

Placement of Devireg 530, 531, and 532

Connection diagrams for Devireg 530, 531, and 532

Devireg 530 Connection Diagram

Illustrates the wiring and terminal connections for the Devireg™ 530 thermostat.

Devireg 531 Connection Diagram

Illustrates the wiring and terminal connections for the Devireg™ 531 thermostat.

Devireg 532 Connection Diagram

Illustrates the wiring and terminal connections for the Devireg™ 532 thermostat.

Contactor Wiring for Higher Loads

Diagrams showing how to use contactors for loads exceeding 15A or with multiple elements.

Trouble shooting

No Light Troubleshooting

Steps to take if the thermostat does not illuminate when powered on.

Technical specifications for Devireg 530, 531, and 532

DEVI devireg 531 Specifications

General IconGeneral
Temperature range+5°C to +45°C
Voltage230V AC
IP ClassIP20
Ambient temperature-10°C to +30°C
Protection classClass II
TypeElectronic thermostat
Power supply230V AC
ControlOn/Off
InstallationWall-mounted
MountingWall mounting
Dimensions85 x 85 x 36 mm