DEVIreg™ Smart
5Installation Guide
Frost protection
temperature
5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. floor: 20-35°C (if unrecov-
erable seal is broken then up
to 45°C). Min. floor: 10-35°C,
only with combination of room
and floor sensor.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch off the heating if the
sensor is disconnected or
short-circuited
Cable specification max. 1x4 mm
2
or 2x2,5 mm
2
Ball pressure test temperature 75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
IP class 21