EasyManua.ls Logo

DeVilbiss 4650D - Compressor Cleaning; Filter Change Guide; Maintenance and Service; Specifications

DeVilbiss 4650D
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN - 6 A-4650D
COMPRESSOR CLEANING
1. With power switch in the “Off” position, unplug power cord from wall outlet.
2. Wipe outside of the compressor cabinet with a clean damp cloth every few days to keep dust-free.
DANGER
Do not submerge in water; doing so will result in compressor damage.
FILTER CHANGE
1. Filtershouldbechangedevery6monthsorsooneriflterturnscompletelygrayincolor.
2. Removeltercapbygraspingitrmlyandpullingoutoftheunit
3. Removedirtylterwithngersanddiscard.
4. ReplacewithanewDeVilbisslter(part#5650D-602).AdditionalltersshouldbepurchasedfromyourDeVilbiss
provider.
5. Pushltercapwithnewlterintoposition.
CAUTION– Do not reuse or wash lter or substitute any other material such as cotton for a DeVilbiss air-inlet lter. It will
result in compressor damage.
NOTE An extra lter is packaged with the 4650 series units.
MAINTENANCE
AllmaintenancemustbeperformedbyaqualiedDeVilbissproviderorauthorizedservicecenter.
DANGER
Electric shock hazard. Do not remove compressor cabinet. All disassembly and maintenance must be done by a
qualied DeVilbiss provider.
SPECIFICATIONS
Size......................................................... 7” W x 3.8” H x 13” D (18 cm x 10 cm x 33 cm)
Weight ...............................................................................5.3 lbs. (2.40 kg)
Electrical Requirements ....................................................2.5 amps, 115 VAC (±10%) 60 Hz
Sound Level ...............................................................................53-57 dBA
Power Consumption..................................................................140 watts maximum
Maximum Compressor Pressure .........................................................35 psig (241 kPa)*
Compressor Free Air Flow .......................................................................13 lpm*
Operating Temperature Range .................................................+40° to +104°F (+5 to +40°C)
Operating Humidity .............................................................up to 95% non-condensing
Storage/Transport Temperature Range ..........................................-40° to +158°F (-40° to +70°C)
Storage/Transport Humidity .......................................................up to 95% non-condensing
Supplied Nebulizer Capacity ...................................................................10 ml (cc)
Supplied Nebulizer Nebulization Rate ..................................................0.15 ml/min or greater*
Supplied Nebulizer MMAD ..............................................................5 microns or less**
* Conditions may vary based on altitude above sea level, barometric pressure, and temperature.
**Value determined with minimum ow rate through the nebulizer (20°C, sea level).
There are no hazardous materials used in the construction of this unit, therefore, there are no known risks associated with
disposal of the equipment.

Related product manuals