CA PROP
65
PROP 65 WARNING
WARNING: This product contains chemicals known
to the State of California to cause cancer and birth
defects or other reproductive harm.
Ref. Replacement Individual
No. Part No. Description Parts Req.
1 13-0041 Water Separator Filter 1
(HAF-502)
2 HAF-505 Oil Coalescing Filter 1
3 --- Desiccant Dryer 1
4 HAR-507 Air Regulator 1
5 GA-288 Gauge 1
6 VA-542 Ball Valve 1
*7 DAD-1 Replacement Desiccant
(Not shown)
1
(1 Humidity Indicator Paper
Included)
8 DAD-8 Air Filter, (inside of tank) 2
9 DAD-400 Humidity Indicator (1 Humidity 1
Indicator Paper Included)
10 PT-417 Desiccant Tank (without desiccant) 1
(Includes Ref. No. 8)
11 HAF-404 Filter Change Indicator 1
12 DAD-600 Dessicant Tune-Up Kit
(Not shown)
1
Includes 1 each: DAD-1 and HAF-6.
13 DAD-600-1 Complete Tune-Up Kit
(Not shown)
1
Includes 1 each: DAD-1, HAF-28,
and HAF-6.
14
SSG-8217-K2
O-Ring Kit (2) 1
15 PT-96 Pipe Plug, Special, 1-1/2 NPT 2
16 VA-595 Main Air Supply Shut Off Valve 1
(Not shown)
*The Safety Data Sheet (SDS) is available upon request.
Figure 1
DAD-500 25 CFM Desiccant Air Dryer
DESCRIPTION
The 25 CFM DAD-500 Desiccant Air Drying System
is designed to be a point of use system. It is capable
of removing dirt, water, oil and water vapor from
compresssed air. It consists of a filter separator,
coalescing filter, desiccant dryer, air regulator and main
air supply shut off valve.
SPECIFICATIONS
13-0041 (HAF-502) Water Separator Filter - See page 4:
Air Inlet 1/2" NPT(F)
Air Outlet 1/2" NPT(F)
Air Flow Capacity 100 CFM
Maximum Operating Pressure 150 PSIG (10.3 Bar)
Maximum Temperature 150° F (65.6°C)
Automatic Drain Standard
Filter 5 micron
HAF-505 Oil Coalescing Filter - See page 5:
Air Inlet 1/2" NPT(F)
Air Outlet 1/2" NPT(F)
Air Flow Capacity 55 CFM
Maximum Operating Pressure 150 PSIG (10.3 Bar)
Maximum Temperature 150° F (65.6°C)
Automatic Mechanical Drain Standard
Pressure Differential Indicator Standard
Filter 0.01 Micron
Desiccant Dryer - See page 3:
Air Inlet 1/2" NPT(F)
Air Outlet 1/2" NPT(F)
Air Flow Capacity 25 CFM
Maximum Operating Pressure 150 PSIG (10.3 Bar)
Maximum Temperature 150° F (65.6°C)
Humidity Indicator Standard
Water Vapor Removal -40° F Dew Point
HAR-507 Air Regulator - See page 5:
Air Inlet 3/8" NPT(F)
Air Outlet 1/4" NPT(F) (3 ea.)
Air Flow 60 CFM
Maximum Operating Pressure 150 PSIG (10.3 Bar)
Maximum Temperature 120° F (65.6°C)
VA-595 Main Air Supply Shut Off Valve - Not Shown:
Air Inlet and Air Outlet 1/2" NPT(M)
Maximum Operating Pressure 175 PSIG (12.0 Bar)
Shipping Weight: DAD-500 = 35 lbs.
PARTS LIST
Air In
1
4
6
Air Out
5
8
3
2
8
10
9
11
14
14
15
15
EN
SB-6-156-R1 (3/2018)2 / 8www.carlisleft.com