SERVICE BULLETIN
SB-6-105-J
Replaces SB-6-105-H
HARG-510 AIR REGULATOR
AND GAUGE ASSEMBLY
PARTS LIST
Individual
Ref. Replacement Parts
No. Part No. Description Required
1 Air Regulator 1
2 GA-338 Pressure Gauge 1
3 SSP-8217-ZN Swivel Adapter 1/4” 1
NPT(M) X 1/4” NPS(F)
4 H-2008 Nipple 1/4” NPT(M) 1
X 1/4” NPS(M)
See Pg. 2 for breakdown.
IMPORTANT: Read and follow all Instructions and Safety Pre-
cautions before installing, operating or maintaining this equip-
ment. Keep this manual for future reference.
Improper use can cause bodily injury or equipment dam-
age. Read the following:
• Thisairregulatorandgaugeassemblyisintendedonly
for use in general service air systems. Do not use for
liquids or gases other than air.
• Donotusewherepressureortemperaturecanexceed
rated operating conditions (see specifications).
• Regulatedoutletpressuremust neverbeset higher
thanthemaximumoperatingpressureofthedown-
stream air tool or equipment. An outlet pressure gauge
should always be used.
The accuracy of the indication of pressure gauges can
change during shipment and normal use. If gauge
accuracy is necessary for preventing risks of injury or
property damage, the gauge should be checked before
use and on a routine periodic basis. (See ANSI B40-1974
for gauge standards.)
SPECIFICATIONS
Type Diaphragm, relieving
Inlet Size (Nipple) 1/4” NPS(M)
Outlet Size (Swivel Adapter) 1/4” NPS(F)
Gauge Port Size (two) in Regulator 1/8” NPT(F)
Gauge Range 0-160 PSIG
Rated Operating Conditions:
Inlet Pressure
300 PSIG max.
Temperature 0° to 150° F with dewpoint
less than air temp. below 35° F
*Outlet pressure adjustment range 5 to 100 PSIG.
*Note
Thisrangeisnotminimumormaximumoutletpressure
limit for the regulator. The regulator can be adjusted to
zero PSIG outlet pressure and to pressures higher than
100 PSIG. However, this regulator should not be used to
control pressures outside this specified range.
CONSTRUCTION MATERIALS
Bonnet and Valve Seat ............................ Acetal
Diaphragm ......................... Teflon/Buna-N/Teflon
Body ............................................ Zinc
Valve ..........................................Teflon
2
4
3
1
Adjusting Knob
DESCRIPTION
This unit is used in a compressed air system to maintain a nearly
constant outlet pressure despite change in inlet air pressure and
changes in downstream flow requirements. It is also used for
finer control of air at the spray device. The air setting can be
locked in place by pushing the adjusting knob downward.
CA PROP
65
PROP 65 WARNING: This product contains chemicals
known to the State of California to cause cancer and birth
defects or other reproductive harm.

Other manuals for DeVilbiss HARG-510

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeVilbiss HARG-510 and is the answer not in the manual?

DeVilbiss HARG-510 Specifications

General IconGeneral
BrandDeVilbiss
ModelHARG-510
CategoryController
LanguageEnglish

Related product manuals