PARTS LIST
Individual
Ref. Replacement Parts
No. Part No. Description Required
1 Air Regulator 1
2 GA-338 Pressure Gauge 1
3 SSP-8217-ZN Swivel Adapter 1/4” 1
NPT(M) X 1/4” NPS(F)
4 H-2008 Nipple 1/4” NPT(M) 1
X 1/4” NPS(M)
See Pg. 2 for breakdown.
IMPORTANT: Read and follow all Instructions and Safety
Precautions before installing, operating or maintaining this
equipment. Keep this manual for future reference.
Improper use can cause bodily injury or equipment
damage. Read the following:
This air regulator and gauge assembly is intended only
for use in general service air systems. Do not use for
liquids or gases other than air.
Do not use where pressure or temperature can exceed
rated operating conditions (see specifications).
Regulated outlet pressure must never be set higher
than the maximum operating pressure of the down-
stream air tool or equipment. An outlet pressure gauge
should always be used.
The accuracy of the indication of pressure gauges can
change during shipment and normal use. If gauge
accuracy is necessary for preventing risks of injury or
property damage, the gauge should be checked before
use and on a routine periodic basis. (See ANSI B40-1974
for gauge standards.)
SPECIFICATIONS
Type Diaphragm, relieving
Inlet Size (Nipple) 1/4” NPS(M)
Outlet Size (Swivel Adapter) 1/4” NPS(F)
Gauge Port Size (two) in Regulator 1/8” NPT(F)
Gauge Range 0-160 PSIG
Maximum Air Flow Rate 15 SCFM
Rated Operating Conditions:
Inlet Pressure
300 PSIG max.
Temperature 0° to 150° F with dewpoint
less than air temp. below 35° F
*Outlet pressure adjustment range 5 to 100 PSIG.
*Note
This range is not minimum or maximum outlet pressure
limit for the regulator. The regulator can be adjusted to
zero PSIG outlet pressure and to pressures higher than
100 PSIG. However, this regulator should not be used to
control pressures outside this specified range.
CONSTRUCTION MATERIALS
Bonnet and Valve Seat ............................ Acetal
Diaphragm ........................... PTFE/Buna-N/PTFE
Body ............................................ Zinc
Valve ...........................................PTFE
2
4
3
1
Adjusting Knob
DESCRIPTION
This unit is used in a compressed air system to maintain a nearly
constant outlet pressure despite change in inlet air pressure and
changes in downstream flow requirements. It is also used for
finer control of air at the spray device. The air setting can be
locked in place by pushing the adjusting knob downward.
SB-6-105-R2 (4/2019) 1 / 4 www.carlisleft.com
IMPORTANT! DO NOT DESTROY
It is the Customer's responsibility to have all operators and service personnel read and understand this manual.
Contact your local DeVilbiss representative for additional copies of this manual.
READ ALL INSTRUCTIONS BEFORE OPERATING THIS DEVILBISS PRODUCT.
EN
SERVICE MANUAL
HARG-510 AIR REGULATOR
AND GAUGE ASSEMBLY

Other manuals for DeVilbiss HARG-510

Question and Answer IconNeed help?

Do you have a question about the DeVilbiss HARG-510 and is the answer not in the manual?

Summary

Safety and Operation Guidelines

General Safety Warnings

Key safety precautions for using the air regulator and gauge assembly to prevent injury or damage.

Gauge Accuracy Caution

Important notes on checking pressure gauge accuracy for safe operation and to prevent property damage.

Product Technical Details

Specifications and Parts

Details on product specifications, including size, range, flow rate, and a list of replaceable parts.

Unit Description

Overview of the air regulator's function in maintaining stable air pressure and controlling flow.

Installation and Cleaning Procedures

Installation Instructions

Guidance on correctly installing the regulator in air systems, considering orientation and piping.

Cleaning and Reassembly

Instructions for cleaning parts with soap and water, and reassembly with lubrication and torque specifications.

Preventative Maintenance and Warranty

Disassembly Steps

Detailed steps for disassembling the regulator, emphasizing safety precautions before starting.

Warranty Policy

Information on the product's limited warranty, voiding conditions, and contact details for support.

Summary

Safety and Operation Guidelines

General Safety Warnings

Key safety precautions for using the air regulator and gauge assembly to prevent injury or damage.

Gauge Accuracy Caution

Important notes on checking pressure gauge accuracy for safe operation and to prevent property damage.

Product Technical Details

Specifications and Parts

Details on product specifications, including size, range, flow rate, and a list of replaceable parts.

Unit Description

Overview of the air regulator's function in maintaining stable air pressure and controlling flow.

Installation and Cleaning Procedures

Installation Instructions

Guidance on correctly installing the regulator in air systems, considering orientation and piping.

Cleaning and Reassembly

Instructions for cleaning parts with soap and water, and reassembly with lubrication and torque specifications.

Preventative Maintenance and Warranty

Disassembly Steps

Detailed steps for disassembling the regulator, emphasizing safety precautions before starting.

Warranty Policy

Information on the product's limited warranty, voiding conditions, and contact details for support.

Overview

The DeVilbiss HARG-510 Air Regulator and Gauge Assembly is a device designed for use in compressed air systems to maintain a nearly constant outlet pressure despite changes in inlet air pressure and downstream flow requirements. It also provides finer control of air at the spray device. The air setting can be locked in place by pushing the adjusting knob downward.

Important Safety and Usage Information:

  • This assembly is intended only for general service air systems; it should not be used for liquids or gases other than air.
  • Do not use where pressure or temperature can exceed rated operating conditions.
  • The regulated outlet pressure must never be set higher than the maximum operating pressure of the downstream air tool or equipment. An outlet pressure gauge should always be used.
  • The accuracy of pressure gauges can change during shipment and normal use. If accuracy is critical for preventing injury or property damage, the gauge should be checked before use and on a routine periodic basis (refer to ANSI B40-1974 for gauge standards).
  • Do not submerge the regulator in spray gun solvents or use solvents to clean regulator parts, as this can damage the gauge or regulator components.
  • Risk of injury from pressurized components: Always turn off inlet air pressure and bleed off remaining pressure before disassembly.

Technical Specifications:

  • Type: Diaphragm, relieving
  • Inlet Size (Nipple): 1/4" NPS(M)
  • Outlet Size (Swivel Adapter): 1/4" NPS(F)
  • Gauge Port Size (two) in Regulator: 1/8" NPT(F)
  • Gauge Range: 0-160 PSIG
  • Maximum Air Flow Rate: 15 SCFM
  • Rated Operating Conditions:
    • Inlet Pressure: 300 PSIG max.
    • Temperature: 0° to 150° F with dewpoint less than air temperature below 35° F
  • Outlet Pressure Adjustment Range: 5 to 100 PSIG. While the regulator can be adjusted to zero PSIG and to pressures higher than 100 PSIG, it should not be used to control pressures outside this specified range.

Construction Materials:

  • Bonnet and Valve Seat: Acetal
  • Diaphragm: PTFE/Buna-N/PTFE
  • Body: Zinc
  • Valve: PTFE

Installation:

  1. Install the regulator as close as possible to the device being serviced. It can be installed at any angle.
  2. In systems with a cyclic demand, install the regulator upstream of cycling control valves.
  3. Air line piping should be the same size as the regulator ports.
  4. Air flow must be in the same direction as the arrow on the bottom of the regulator body.

Operation:

  1. Before turning on system air pressure, turn the adjusting knob full counterclockwise. This closes the regulator to produce zero air pressure. The knob locks in position when pushed downward towards the regulator body.
  2. Turn on system air pressure.
  3. Turn the regulator adjusting knob clockwise until the desired outlet pressure is reached.
  4. To avoid minor readjustment after making a change in pressure setting, always approach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than that desired, then bring up to the desired point. Lock the pressure setting by pushing the knob downward.

Preventative Maintenance and Cleaning:

  1. Clean parts using warm water and soap.
  2. Inspect all parts and replace any damaged ones.

Disassembly for Maintenance:

  1. Turn the regulator knob counterclockwise until it stops.
  2. Unscrew the bonnet from the regulator body.
  3. Remove the adjusting screw and nut, then the regulating spring (4), slip ring (5), and diaphragm (6).
  4. Using a screwdriver, unscrew the valve seat (7) and o-ring (8).
  5. Remove the valve (9) and valve spring (10).

Reassembly:

  1. Apply a small amount of lubricant SSL-10 gun lube to the adjusting screw threads inside the bonnet.
  2. Torque the valve seat (7) to 4-6 in./lbs. (do not overtighten).
  3. Torque the bonnet to 50-60 in./lbs.

Parts List (Key Components):

  • GA-338: Air Regulator (1 required)
  • SSP-8217-ZN: Pressure Gauge (1 required)
  • H-2008: Swivel Adapter 1/4" NPT(M) X 1/4" NPS(F) (1 required)
  • Nipple 1/4" NPT(M) X 1/4" NPS(M) (1 required)
  • Included in KK-4887-2 Regulator Kit: Slip Ring, Diaphragm (PTFE Protected), Valve Seat, O-ring, Valve (PTFE), Valve Spring.

DeVilbiss HARG-510 Specifications

General IconGeneral
BrandDeVilbiss
ModelHARG-510
CategoryController
LanguageEnglish