Gauge - When replacing this item , screw a new gauge in by hand only, do not use a spanner. Seal
the thread using a liquid sealant, do not use PTFE tape.
Coalescer/ Activated carbon filter - To replace this item, unscrew and remove the bowl, then unscrew
the filter element. Care should be taken when replacing the element not to cross the threads.
Filter - To replace these items unscrew and remove bowl, unscrew the central bolt and pull the filter
down.
Always de-pressurise the whole unit prior to carrying out any maintenance work, ensuring no pressure
is locked in the unit or items attached to it. The regulator knob should be wound fully counter
clockwise to exhaust all pressure after isolating.
Always use recommended and original parts and accessories.
MAINTENANCE
Ensure earthing of the unit is not affected by maintenance activities, see installation on previous page.
Filter/ Coalescer/ Activated carbon filter periods for replacement
It is recommended that filter elements are replaced periodically i.e. when a drop in pressure is
noticeable through the unit or every 6 months or 1000 hours use.
Do not use solvents or aggressive chemicals to clean the unit, which may affect the materials of
construction.