23
English
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
10 Hole in air hose Replace air hose.
11 Check valve restricted Remove, clean or replace.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace.
14 Unit operating in damp or humid conditions Move unit to a dry well ventilated area
15 Restricted air intake filter Clean or replace air intake filter
16
Engine or pump oil is low Add same type of oil in crankcase to pump. See
Compressor Pump Oil under Maintenance.
17
Carbon build-up in pump. Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
18
Detergent type oil being used in pump Drain oil and refill pump using DeWALT synthetic or SAE
40, non-detergent air compressor oil.
19
Motor overload protection switch has tripped
See Motor Overload under Features.
20
Extension cord is wrong length or gauge
Check for proper gauge wire and cord length. See
Extension Cords under Installation.
21
Loose electrical connections
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
22
Possible defective motor or starting capacitor
Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
23
Paint spray on internal motor parts Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center. Do not operate the compressor
in the paint spray area. See flammable vapor warning.