24
English
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
24
Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as
necessary. Reset circuit breaker. Do not use a fuse or
circuit breaker with higher rating than that specified
for your particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper
extension cord.
4. Disconnect the other electrical appliances from circuit
or operate the compressor on its own branch circuit.
25
Tank pressure exceeds pressure switch cut-in pressure Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.
26
Pressure release valve on pressure switch has not
unloaded head pressure
Set the On/Off switch to OFF. If the valve does not open,
replace switch. Contact a D
e
WALT factory service center
or a D
e
WALT authorized service center.

Related product manuals