As highlighted in slide 9 , it is important to note that the motor will shut down
at a defined current that is measured at the micro processor. In order to
determine at which setting we are at a defined value of voltage is measured.
To give an example :
If we are at torque setting 6, it will detect this position by design, correct
voltage will be measured. The correct specification 1.205v to 1.480v .
Within this range the micro processor will detect X voltage and therefore
cut voltage to the unit.