ENGLISH
7
• Disconnect the plug from the supply.
• Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
• Only fit 13 Amperes BS1363A approved plugs
fitted with the correctly rated fuse (1).
• The cable wire colours, or a letter, will be
marked at the connection points of most good
quality plugs. Attach the wires to their respective
points in the plug (see below). Brown is for Live
(L) (2) and Blue is for Neutral (N) (4).
• Before replacing the top cover of the mains plug
ensure that the cable restraint (3) is holding the
outer sheath of the cable firmly and that the two
leads are correctly fixed at the terminals crews.
1
2
4
3
WARNING: NEVER use a light socket.
NEVER connect the live (L) or
neutral (N) wires to the earth
pin marked E or .
Using an Extension Cable
An extension cord should not be used unless
absolutely necessary. Use an approved extension
cable suitable for the power input of your charger
(see technical data). The minimum conductor size is
1 mm
2
; the maximum length is 30 m.
Also refer to the table below.
Conductor size (mm
2
) Cable rating (Amperes)
0.75 6
1.00 10
1.50 15
2.50 20
4.00 25
Cable length (m)
7.5 15 25 30 45 60
Voltage Amperes Cable rating (Amperes)
115 0 – 2.0 6 6 6 6 6 10
2.1 – 3.4 6 6 6 6 6 15
3.5 – 5.0 6 6 10 15 20 20
5.1 – 7.0 10 10 15 20 20 25
7.1 – 12.0 15 15 20 25 25 –
12.1 – 20.0 20 20 25 – – –
230 0 – 2.0 6 6 6 6 6 6
2.1 – 3.4 6 6 6 6 6 6
3.5 – 5.0 6 6 6 6 10 15
5.1 – 7.0 10 10 10 10 15 15
7.1 – 12.0 15 15 15 15 20 20
12.1 – 20.0 20 20 20 20 25 –
When using a cable reel, always unwind the cable
completely.
Voltage Drops
Inrush currents cause short-time voltage drops.
Under unfavourable power supply conditions, other
equipment may be affected.
If the system impedance of the power supply is
lower than 0.25 ø, disturbances are unlikely to
occur.
ASSEMBLY AND ADJUSTMENTS
WARNING: To reduce the risk of
injury, turn unit off and disconnect
machine from power source before
installing and removing accessories,
before adjusting or changing set-ups
or when making repairs. Be sure the
trigger switch is in the OFF position. An
accidental start-up can cause injury.
Trigger Switch (fi g. 1, 2)
WARNING: Grasp tool firmly with both
hands to maintain control of the tool at
start up and during use and until the
wheel or accessory stops rotating. Make
sure the wheel has come to a complete
stop be fore laying the tool down.
NOTE: To reduce unexpected tool movement,
do not switch the tool on or off while under load
conditions. Allow the grinder to run up to full speed
before touching the work surface. Lift the tool from
the surface before turning the tool off. Allow the tool
to stop rotating before putting it down.