Page 3 of 12
Dewhot | Gas geyser manual
Page 2 of 12
Dewhot | Gas geyser manual
Hot water output 25~ 6lt 8lt 10lt 12lt 16lt 20Lt
Rated input (KW) 12 16 20 24 32 40
Rated output (KW) 10.8 14.4 18 21.6 28.8 36.8
Gas consumption LPG 0.93 kg/hr 1.24 kg/hr 1.55 kg/hr 1.86 kg/hr 2.65 kg/hr 3.01 kg/hr
Water flow min 180 lt/hr 240 lt/hr 300 lt/hr 320 lt/hr 360 lt/hr 600 lt/hr
Water flow max 360 lt/hr 480 lt/hr 600 lt/hr 720 lt/hr 960 lt/hr 1200 lt/hr
Flue diameter 90 mm 110 mm 110 mm 110 mm 125 mm 126 mm
Dimension (W, H, D) 290*430*130 320*520*150 330*590*150 330*620*150 380*680*180 430*730*180
Packed dimension 350*565*180 385*645*200 395*720*200 395*755*200 436*845*260 485*885*260
Net weight 4.6 kg 6.5 kg 7.2 kg 8.0 kg 11.5 13.2 kg
Gross weight 6 kg 7.5 kg 8.5 kg 9.35 kg 13.5 14.5 kg
Safety devices
• Water over heating protection (75oC)
• Exhaust over heating (145)
• Flame out gas cut off
• Low flow cut off
• Non return valve
• Anti frost protection
Parameters
• Gas type, LPG
• Gas pressure 2 000-2800 pa
• Solenoid lifetime 300,000 times
• Water pressure min 0.25 bar
• Water pressure max 5.0 bar
Features
• Domestic instant water heater with
natural exhaust;
• Water gas linked automatic ignition,
• No pilot light;
• Automatic pulse ignition from two
standard torch batteries;
• Stainless steel 310 front panel;
• LCD temperature gauge;
• Flame height, gas flow switch;
• Temperature, water flow
rate switch;
• On & off nob for cold or hot water;
• Low water pressure starting;
• Water pressure stabilizing design;
• Starting indicator light;