Do you have a question about the Deye SUN-60K-G and is the answer not in the manual?
Model | SUN-60K-G |
---|---|
Rated Power | 60 kW |
Max. DC Input Power | 90 kW |
Max. DC Input Voltage | 1100 V |
Start-up Voltage | 250 V |
MPPT Voltage Range | 200-1000 V |
Number of MPPT Trackers | 4 |
Number of Strings per MPPT Tracker | 2 |
Rated AC Output Power | 60 kW |
Max. AC Output Power | 66 kW |
Rated AC Voltage | 400 V |
THDI | <3% |
Rated Grid Frequency | 50/60 Hz |
Max. Efficiency | 98.6% |
Euro Efficiency | 98.2% |
MPPT Efficiency | 99.9% |
DC Switch | Yes |
Protection Degree | IP65 |
MPPT Range | 200-1000 V |
Maximum Input Current per MPPT | 26 A |
Output Voltage | 400 V |
Output Frequency | 50/60 Hz |
Power Factor | 0.8 leading to 0.8 lagging |
Protection | DC Reverse Polarity Protection |
Operating Temperature Range | -25°C to 60°C |
Cooling | Smart Cooling |
Communication | RS485 |
Type | Three-phase |
Describes the front and bottom views of the grid-tied PV string inverter.
Lists all included components of the grid-tied PV string inverter package.
Explains the meaning of various safety symbols used in the manual.
Provides essential safety instructions for electrical installation and operation.
Offers important precautions and recommendations for the safe use of the inverter.
Shows the front panel display of the inverter with buttons.
Details the function and meaning of the four status indicator lights on the panel.
Describes the function of the four buttons on the inverter's front panel.
Explains the content displayed on the inverter's LCD screen.
Provides criteria for choosing a suitable installation location for the inverter.
Guidelines for inverter mounting angle, spacing between units, and placement.
Provides dimensions for the inverter mounting bracket.
Details the steps for installing the inverter onto the wall using the mounting bracket.
Instructions for connecting the DC input terminals of the inverter.
Details the connection of AC cables to the inverter's terminal block.
Explains the importance and method for grounding the inverter.
Describes how to connect the inverter for remote monitoring via WiFi.
Instructions for installing the datalogger accessory for monitoring.
Step-by-step procedure for safely starting up the inverter.
Step-by-step procedure for safely shutting down the inverter.
Provides a wiring diagram for the SUN limiter zero-export function.
Detailed steps for connecting the SUN limiter to the inverter and grid.
Instructions for configuring and debugging the zero-export limiter function.
Explains zero-export using an energy meter and lists compatible models.
Provides important safety and operational notes for the zero-export function.
Guide to viewing load power and system data on the monitoring platform.
Describes the information displayed on the inverter's initial LCD screen.
Explains how to access and view statistical data, including daily, monthly, and yearly history.
Describes how to view the fault history and error codes on the inverter.
Instructions for turning the inverter ON and OFF via the LCD interface.
Guide to setting various system, run, protect, and communication parameters.
Details settings for time, language, display, and factory data reset.
Configuration options for protection parameters like over/under voltage and frequency.
Settings for communication parameters such as address and baud rate.
Lists and explains various error codes and their potential causes.