Do you have a question about the Deye SUN-6K-G03-LV and is the answer not in the manual?
Model | SUN-6K-G03-LV |
---|---|
Type | Hybrid Inverter |
Rated Output Power | 6000 W |
Max. AC Output Power | 6600 VA |
Max. DC Input Power | 7800 W |
Start-up Voltage | 150 V |
Number of MPPT Trackers | 2 |
Max. Input Current per MPPT | 13 A |
Nominal AC Voltage | 230 V |
AC Voltage Range | 180-280V |
Max. Output Current | 28.7 A |
Power Factor | 0.8 leading to 0.8 lagging |
THDi | <3% |
Battery Voltage Range | 40-60V |
Max. Charging Current | 120 A |
Max. Discharging Current | 120 A |
Protection Degree | IP65 |
Efficiency (max) | 97.6% |
AC Grid Frequency Range | 50 Hz / 60 Hz |
Battery Type | Lithium-ion |
Communication | RS485 |
Operating Temperature Range | -25°C to +60°C |
Input Voltage Range | 125-550V |
Introduces the on-grid inverter and its appearance.
Lists all included parts for the inverter.
Explains safety symbols used in the manual.
Provides essential safety guidelines for operation.
Lists important precautions and requirements for using the inverter.
Displays the front panel of the inverter with its indicators.
Explains the meaning of each LED status indicator light.
Describes the function of front panel buttons and the LCD screen.
Guides on choosing the appropriate location for inverter installation.
Explains the process of mounting the inverter on a wall.
Details how to connect the DC input terminals.
Guides on connecting the AC input terminals.
Explains the importance and method of grounding the inverter.
Recommends installing a circuit breaker for overcurrent protection.
Explains how to connect the inverter for remote monitoring.
Lists conditions for startup and procedures for shutting down the inverter.
Explains the optional Anti-PID function.
Details wiring diagrams for the Eastron SDM630-Modbus V2 meter.
Provides connection diagrams for Eastron MCT and CHNT meters.
Explains setup for multiple inverters with a single meter.
Step-by-step guide to enable and use the zero-export function.
Provides precautions for zero export and how to monitor load power.
Describes information displayed on the initial inverter interface.
Introduces the submenus available in the main menu.
Covers system parameters and running parameters, including password.
Explains the inverter's over-frequency response function.
Explains various reactive power regulation modes like Q(%), PF, Q(U), Q(P).
Describes protection parameter settings, noting it's for engineers.
Details communication parameter settings like Address and BaudRate.
Provides guidance on cleaning and maintaining the inverter.
Lists error codes, descriptions, and solutions for the inverter.
Provides detailed technical specifications of the inverter.