EasyManuals Logo

DeZurik G Series Instruction

DeZurik G Series
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
DeZURIK
Cylinder Operated G-Series Actuator
D10022 Page 8 August 2012
Adjusting Position Stops (Continued)
Table D: Cylinder Closing Pressure - Reverse Pressure Drop*
Valve Size
Actuator &
Cylinder
Cylinder Closing Pressure
(For Direct Pressure Drop Use Same as 25# Reverse)
172 kPa 50 psi 344 kPa 75 psi 517 kPa 100 psi 689 kPa
18” (450mm)
G12-C6
G12-C8
G12-C10
G16-C8
G16-C10
G16-C12
G16-C10B10
G16-C10B12
G16-C12B12
G16-C12B10B10
20” (500mm)
G12-C8
G12-C10
G16-C8
G16-C10
G16-C12
G16-C10B10
G16-C10B12
G16-C12B12
G16-C12B10B10
24” (600mm)
G16-C8
G16-C10
G16-C12
G16-C10B10
G16-C10B12
G16-C12B12
G16-C12B10B10
G16-C12B12B12
30” (750mm)
G16-C8
G16-C10
G16-C12
G16-C10B10
G16-C10B12
G16-C12B12
G16-C12B10B10
G16-C12B12B12
36” (900mm)
G16-C10B12
G16-C12B12
G16-C12B10B10
G16-C12B12B12
* Reverse Pressure Drop: The pressures specified for reverse pressure drop will provide tight pressure shutoff or minimum
leakage with maximum plug life.
If a dead-tight shutoff with reverse pressure is required, contact DeZURIK