USER MANUAL
PEC-A-3500-1M
PORTABLE EVAPORATIVE COOLER
Thank you for choosing Dial.
Please read this User Manual before using this Portable Evaporative Cooler
Retain the manual for future reference.
Attention: If you are experiencing difficulty with your portable evaporative cooler, do not return it to
the place of purchase. Contact Dial Manufacturing for help or disposition.
Dial Manufacturing, Inc.
25 South 51st Avenue, Phoenix, AZ 85043
1-800-350-DIAL | customerservice@dialmfg.com

Questions and Answers

  • C
    Christina BurgessAug 5, 2025
    What to do if the DIAL PEC-A-3500-1M Air Cleaner fan does not operate or runs slow?
    • M
      michael49Aug 5, 2025
      If your DIAL Air Cleaner fan isn't operating or runs slowly, begin by checking the GFCI plug on the power cord to ensure it's properly plugged into the electrical outlet. If it still doesn't work, try resetting the GFCI outlet or using a non-GFCI outlet. Also, make sure the 'FAN' dial is set to 'L, M or H' to turn on the evaporative cooler. Check for a faulty motor capacitor, which may need replacing (for select models).
  • C
    Charles BarnettAug 10, 2025
    Why is my DIAL Air Cleaner not blowing cold air?
    • D
      derek76Aug 11, 2025
      If your DIAL Air Cleaner isn't producing cool air, first ensure the 'PUMP' dial is switched to 'ON' to activate the pump. Then, fill the reservoir with water, making sure it's at least half full, before activating the pump. Also, check the pump and pump hose for any clogs and clear any debris. If the problem persists, the pump may be defective and require replacement.
  • A
    Alexis MooreAug 15, 2025
    How to stop my DIAL PEC-A-3500-1M from leaking?
    • K
      Kathleen DunnAug 15, 2025
      To address leakage in your DIAL Air Cleaner, inspect the Drain Plug and Cap to ensure the Drain Plug is fully plugged and the Cap is tightened completely. Also, inspect the Reservoir for cracks or damage. Check for Media Pad scale build-up and check for leaks from the Water Spreader/Distributor Rail and hose connections.
  • D
    Dr. Steven HolmesAug 20, 2025
    Why is the vertical louvre not working on my DIAL PEC-A-3500-1M?
    • C
      Christy BarkerAug 20, 2025
      If the vertical louvre on your DIAL Air Cleaner isn't working, make sure the 'SWING' dial is set to 'ON.' If that doesn't solve the issue, check the oscillation motor for proper connection and any defects.
  • P
    Patricia VillaAug 25, 2025
    What to do if I have issues with the float valve in my DIAL PEC-A-3500-1M Air Cleaner?
    • L
      Lisa AveryAug 26, 2025
      To resolve issues with the float valve in your DIAL Air Cleaner, adjust the valve if the water level is too low or too high. Inspect the float valve for cracks that could cause failure and water leakage, and replace the valve if cracked.
  • G
    gjohnsonAug 30, 2025
    Why does my DIAL PEC-A-3500-1M Air Cleaner emit an odor?
    • P
      Patrick AlexanderAug 30, 2025
      When you first use your DIAL Air Cleaner, the Rigid Media Pad may emit an odor, but this should dissipate within a week. If the odor persists, the Media Pad may have developed mold or bacterial growth, in which case you should replace the Media Pad.

Summary

Safety Instructions

Applications

Features

Specifications

How Evaporative Air Coolers Work

Exterior Parts of the Evaporative Cooler

Unpacking and Installing the Casters

Control Panel Operations

Fan

Use dial to select fan speed (Low, Medium, High) and turn on fan.

Pump

Turn dial to "ON" to activate evaporative cooling. Ensure water level is sufficient.

Swing

Turn dial to "ON" to activate airflow oscillation left to right.

Operating the Evaporative Cooler

Fill the Reservoir

Fill reservoir manually or via hose. Ensure water level is at least half full for cooling.

Using Ice Pack (Optional)

Place frozen ice packs in the top water tray to chill water before it flows through media pads.

Plug in the GFCI Plug

Connect GFCI plug to a suitable outlet after pressing "Re-set". Re-set outlet if needed.

Maintenance

Cleaning the Exterior Surface of the Evaporative Cooler

Clean housing with duster/moist cloth. Avoid chemical solvents. Use caution around control panel.

Cleaning the Reservoir

Drain, wipe with detergent solution, and rinse reservoir. Clean weekly to reduce mineral deposits.

Maintaining and Changing the Rigid Media Pads

Clean/replace pads based on water conditions. Allow pads to dry after use.

End of Season Maintenance

Empty, clean, dry reservoir. Clean pads. Store unit in a dry place.

Troubleshooting

Cooler Does Not Work

Check GFCI plug, outlet, and ensure FAN dial is set to ON.

No Cool Air

Ensure PUMP is on, water level is sufficient, and pump/hose are not clogged.

Fan Does Not Operate

Check GFCI, outlet, FAN dial setting, and motor capacitor.

Fan Runs Slow

Check for faulty motor capacitor.

Vertical Louvre Does Not Operate

Turn SWING dial to ON. Check oscillation motor.

Leakage

Check drain plug, reservoir for cracks, media pad scale, and hose connections.

Float Valve Issues

Adjust valve for correct water level. Check for cracks on float valve.

Odor Emission

Initial odor dissipates. Replace media pad if mold/bacteria growth suspected.