EasyManua.ls Logo

Diamond G2SA77/9 - Cleaning for Prolonged Deactivation; Summarised Table: Qualification - Operation - Frequency

Diamond G2SA77/9
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
THE PRESENT MANUAL IS PROPERTY OF THE MANUFACTURER. ANY REPRODUCTION, EVEN PARTIAL, IS PROHIBITED.
- 14 -
ROUTINE MAINTENANCE
4.
Summarised table: qualication - operation - frequency
OPERATION FREQUENCY
Cleaning at commissioning Upon arrival after installation
Cleaning appliance Daily
Cleaning parts in contact with foodstuff Daily
Cleaning ue Yearly
Checking thermostat Yearly
Checking micro switch Yearly
Cleaning hotplates (chromed, cast-iron) Daily
Cleaning for prolonged deactivation
When the appliance remains idle for a long time, perform all the described daily cleaning
procedures.
When the operations are over, protect the parts more exposed to oxidation doing as follows.
Use lukewarm water with a bit of soap to clean the parts;
Rinse the parts thoroughly, without using pressurised and/or direct water jets;
Dry the surfaces carefully using non-abrasive material;
Pass over all the stainless steel surfaces using a non-abrasive cloth slightly moistened with
Vaseline to create a protective coating.
For appliances with doors and rubber gaskets, leave the door slightly ajar to let it air out and spread protective
talcum powder on the rubber gasket surfaces.
Air out the appliances and rooms regularly.
Should a problem occur, the generic operator performs the rst search and, if qualied, eliminates
the cause of the problem and restores the appliance correctly.
If the problem cannot be resolved, turn the appliance off, disconnect it from the electrical mains
and shut all the supply valves. Then contact customer service.
The maintenance technician intervenes when the generic operator was not able to pinpoint the
cause of the problem, or whenever restoration of correct operation of the appliance entails executing
operations for which the generic operator is not qualied.
Generic operator
Person authorised and employed to operate the appliance with guards active, capable of performing
routine tasks.
Homogeneous operator
Expert operator authorised for handling, transporting, installing, servicing, repairing and scrapping
the equipment.