EasyManua.ls Logo

Diamond Y2-3 - Page 6

Diamond Y2-3
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual
N.ºMNS00054.00
4.4 Standard cycles selection and description
The standard cycles are designed to facilitate kitchen work. The four Start & Go keys cover most of the daily needs, each corresponding to a
preset cycle.
By pressing one of the keys the blast chiller and
freezer starts the desired cycle.
Three minutes after the start, the equipment checks if the core probe is being used. In
this case, the cycle will be managed by the core probe; otherwise, the cycle will be done
by time.
This cycle reduces food core temperature down to +3ºC within 90 minutes.
Ideal to reduce food temperature such as very thin food, semolina (pasta or rice),
desserts (cream, mousse), vegetables and other delicate products.
This cycle reduces food core temperature down to +3ºC within 90 minutes.
Created to optimize working time and at the same time chilling bulky foods, food with
high fat content, without the formation of “ice skin”.
This cycle reduces food core temperature down to -18ºC within 240 minutes.
Prepared for freezing cooked food including oven dishes or baked dough. Two-phase
freezing cycle; during the first phase the product core temperature reaches +6º C and
during the second phase the product core temperature reaches -18º C.
This cycle reduces food core temperature down to 18ºC within 240 minutes.
Designed for freezing cooked bulky foods and raw foods. Rather quickly, the product
core temperature reaches -18º C and inside the blast freezer the temperature reaches -
35º C.
4.5 Cycles interruption
4.5.1 Intentional interruption
To protect the compressor, it is only possible to interrupt a program one minute after start-up.
Press for three seconds; the cycle will be stopped and cannot be continued.
If you would like to shut down the blast chiller & freezer, press again for three seconds.
4.5.2 Interruption due to door opening
Avoid door opening during operation cycle. If you really need to open it, the opening time should not exceed 30 seconds, otherwise the cycle is
terminated and must be restarted.
4.6 Programming a Customized Cycle
and select SETTINGS
In the main MENU use the keys
pressing .
With the keys enter the manufacturer code 1234 and press
to continue.

Related product manuals