DiBO n.v. 67
Settings (remote control 2)
- Machine o (main switch o) = LED on/o switch does not glow.
- Machine on & functioning ok (main switch on) = LED on/o switch lights continuously irrespective if the on/o
switch will be switched on/o.
- Machine in failure = LED on/o switch flashes, flash frequence depending type o disturbance (see 4.6).
In case of disturbance you can reset this by turning on/o this switch.
4.4. HT pumps
There must be present a pre - pressure (pump) at HT pumps (pumps with high temperature). The pre - pressure
(pump) must provide for sucient flow of water to feed the high pressure pump and to occur cavitation.
Cavitation is the phenomenon that in a moving fluid the local pressure is going to be lower than the vapour pres-
sure of the fluid. Because of this mist bells will arise who can implode with high power in the pump and could
cause damages. For all these applications at high temperature, it is ABSOLUTELY ESSENTIAL to feed the pump
with positive pressure (at least 3 bar) and with a sucient quantity of water.
4.5. Scope of application
Ecient high pressure cleaning is achieved by following a few guidelines combined with your own experiences.
Each cleaning job is dierent and specific, therefore contact DiBO for the best solution in your application sector.
Using cleaning products (if applicable): the surface to clean should be sprayed so the product can act during
some time (do not let it dry!) before cleaning with high pressure jet.
Cleaning agents can increase the cleaning eect if they are used correctly!
Always follow/consider the safety instructions of the used product!
Cold water (high pressure) cleaning: removal of (mild) impurities/pollution and rinsing.
Hot water (high pressure) cleaning (if applicable): the cleaning eect will be such improved through increasing the
temperature (set the temperature experimentally according to the application).
Cleaning via lance with rotating head (if applicable): cleaning method to remove tough layers of dirt.
Cleaning using a steam lance (if applicable): this steam function (by overheating water) is used in ‘sensitive’ clean-
ing applications (eg: damage sensitive surfaces) where there is stubborn dirt (eg: degreaser) is removed by using
steam.
Please note: this application has high cleaning temperatures and requires various safety measures!
4.6. Disturbances IBH-M/L
LED status (flash frequence) Disturbance
1x No flow available
2x No pressure present (pressure switch fault)
3x Thermal protection motor o
4x Flame protection - no flame
5x Flame protection - after burn
6x Pressure regulator fault
7x Leak detection
8x Run dry softener tank