o Select Time Zone
o Deselect "Automatically adjust clock for Daylight Saving Time"
o Click OK
o Select Internet Time
o Deselect "Synchronize with an Internet time server"
o Click OK
Note: You must manually adjust your computer time during the start and
end of Daylight Savings.
Additional Touchscreen User Settings include
Additional Touchscreen User Settings includeAdditional Touchscreen User Settings include
Additional Touchscreen User Settings include:
::
:
Set Channel 1/2 Unit of Measure/Range(s) Menu Setup Set Ranges
Set High/Low Alarms Menu Setup Set Alarms
Alarm Operation
Alarm OperationAlarm Operation
Alarm Operation
Alarm ON: Alarm setting arrows will appear on the graph to indicate min
and max settings. These arrows can be dragged and dropped to adjust
alarm min and max settings.
Alarm Triggered: Out of range alarm setting arrow will blink, the alarm
symbol will display and an audible alarm will sound.
Press the logger’s display to clear the alarm.
If the alarm condition still exists after two minutes, the alarm will sound and
display again.
If the display is not pressed after 30 seconds, the alarm will stop sounding
and beep 2x every 5 minutes until the alarm is cleared.
Note:
Note: Note:
Note: The a
The aThe a
The alarm
larmlarm
larm is inaudible while the unit is battery operated.
is inaudible while the unit is battery operated. is inaudible while the unit is battery operated.
is inaudible while the unit is battery operated.
VIEW
VIEW VIEW
VIEW
There are 3 selectable views; Press the “View” button to scroll through
each view.
Current Readings will update every 10 seconds or per the sample rate,
whichever is greater
Note: The Current Reading Window can be dragged and dropped to set a
new display location.
Minimum and Maximum Readings
Minimum and Maximum ReadingsMinimum and Maximum Readings
Minimum and Maximum Readings
Min/Max readings displayed reflects the Min and Max for all samples
currently displayed
displayeddisplayed
displayed on the graph.
When scrolling through logged data or zooming, the Min/Max readings will
change to reflect the data being displayed.
Scroll Bar
Scroll BarScroll Bar
Scroll Bar
A full graph will trigger the “Scroll” bar icon to display.
Press and drag the bar to the left to view all saved data.
When the scroll bar is in the right most position, the most recently saved
data is displayed on the graph. When in the left most position, the oldest
saved data is displayed on the graph.
Zoom
ZoomZoom
Zoom
Press the ZOOM button to activate Zoom
Place your finger on the graph and drag along the graph to draw a box
over the desired data.
To exit Zoom, press the Unzoom button. The graph will default to the
standard Time Scale with the most recent data displayed.
Screen Lock
Screen LockScreen Lock
Screen Lock
Prevents unauthorized users from clearing the logger or changing settings.
Press Menu, Setup, Set Screen Lock, enter code: 9 3 0
Press OK
Turn the Screen Lock Off/On, set screen lock delay and set new code.
The screen lock will activate once the preset delay period has passed after
the last screen touch.
Contact Dickson if the Screen Lock code is forgotten.
Stop or Wrap When Full
Stop or Wrap When FullStop or Wrap When Full
Stop or Wrap When Full
Your Touchscreen logger is set to log continuously, “wrap when full”. To change, in
DicksonWare, go to Setup Samples to set the logger to “stop when full”.
Display
DisplayDisplay
Display
The Touchscreen Logger display may show colored lines during the start-up
process. This is part of the display testing process; however, the display should
display normally within a few seconds.
The display will show when the unit is battery operated, but the battery will drain
very quickly. The unit should be connected via AC power and the battery should
only be used for backup purposes.
Relays
RelaysRelays
Relays
FH535 features 2 (1 per channel) SPST 24VDC. 0.5A, NO/NC Relays. Relays do not
operate under battery power.
. .
. A
AA
A Relay wiring diagram
Relay wiring diagram Relay wiring diagram
Relay wiring diagram is
is is
is available at
available at available at
available at
http://www.dicksondata.com
http://www.dicksondata.comhttp://www.dicksondata.com
http://www.dicksondata.com.
..
. Pin number 1 is the lowest pin position and Pin
number 6 is the top pin position.
Clear Logger
Clear LoggerClear Logger
Clear Logger
The Touchscreen Logger can be cleared via DicksonWare or by saving a current or
new Time Scale or changing the Date or Time via the Touchscreen Menu.
Power
PowerPower
Power
The Touch Screen logger operates on a 120V AC adapter. A
AA
A
U
UU
UP
PP
PS
SS
S
i
ii
is
ss
s
r
rr
re
ee
ec
cc
co
oo
om
mm
mm
mm
me
ee
en
nn
nd
dd
de
ee
ed
dd
d
for longer backup life.
for longer backup life. for longer backup life.
for longer backup life.
Turning the unit Off via the On/Off switch will stop logging. Backup battery will
continue to charge while the logger is off but still powered via AC.