EasyManua.ls Logo

DIG RBC 8000 - Troubleshooting Valve and Sensor Issues

DIG RBC 8000
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
CAUSE: Valve is installed backwards
SOLUTION: Check flow arrow and verify arrows points away from
water source – reverse valve if necessary
CAUSE: Debris is blocking solenoid port
SOLUTION: Shut off water supply, unscrew and remove solenoid, then open
water supply and flush out solenoid port, re-install solenoid
CAUSE: Flow control knob is too far open
SOLUTION: Turn flow control knob clockwise and retest
CAUSE: Drip System flow rate is below minimum flow rate
SOLUTION: Increase system flow rate by adding or changing drippers
PROBLEM: Rain sensor does not prevent watering
CAUSE: Rain sensor is normally open, malfunctioning, or not wired correctly
SOLUTION: Verify that sensor icon appears on display when pin is pushed
down & check all wire splices
PROBLEM: Timer waters more than once per day
CAUSE: More than one start time has been programmed
SOLUTION: Change start time 2, 3, and 4 to OFF
PROBLEM: Water fails to stop discharging from Air Vent.
CAUSE: Poppet is out of alignment or missing
SOLUTION: Unscrew air vent cap and re-align poppet or replace air vent/poppet
assembly