Scale System
Troubleshooting Guide
for
Digi-Star Scales with
EZ 150, EZ 210 and EZ 320
Indicators
F3214B December 1997
Question and Answer IconNeed help?

Do you have a question about the DIGI-STAR EZ 210 and is the answer not in the manual?

Summary

Indicator Flashes ±RANGE

EZ Series Indicator Troubleshooting Steps

Step-by-step guide for diagnosing and resolving the '±RANGE' flashing error on EZ Series indicators.

Indicator Will Not Come On

No Power to Indicator Diagnosis

Detailed checks for AC power source and DC power output to the indicator.

Indicator Unstable (Drifts)

System Inaccurate Causes

Defective or Misoriented Load Cell

Troubleshooting steps for identifying a bad or incorrectly installed load cell.

Indicator Will Not Balance (Zero)

Junction Box and Load Cell Testing

Inspect Junction Box Wiring

Procedure for checking the integrity and connections of junction box wiring.

Test Junction Box Functionality

Method to verify the junction box is operating correctly.