SM 5100 Operation Manual
46
200) you want.
[*]
S1.1
PLU
0.00
PR-KG
Enter PLU programming.
Enter unit price.(Ex.5.80/kg)
[<<] or [>>]
[5][8][0]
S1.1
PLU
5.80
PR-PCS
Change Unit price of PLU 200
to non-weighing item.
[*]
S1.2
PLU
DFT
0 LAB FR1
Select Label format for 1
st
Label
by press [<<] or [>>] key.
(T1~T12,S,A,B,C,F1~F8 is
available)
[<<] or [>>]
S1.2
PLU
T6
6 LAB FR1
Set the Label format (Ex.T6) by
press [6] or[>>] key.
[*]
S1.3
PLU
NO
0 LAB FR2
Select Label format for 2
nd
Label
by press [<<] or [>>]key.
(F1~F8 only)
[<<] or [>>]
[*]
S1.4
C01.01
S1 A 100
Enter commodity name.(Ex.
CAKE)
OPERATION
DISPLAY
REMARK
PT
kg
/kg
[C][A][K][E]
[*]
S1.4
C02.01
S1 A 100
Enter the 2
nd
line of comm ddity
name.
[*]
S1.5
PLU
EAN
BARCODE
Select the type of BARCODE by
press [X] or [>>].(EAN or ITF)
[*]
S1.6
PLU
DFLT
BARCODE
Select barcode format by press
[<<] or [>>]
key.(Ex.2f5c4i4wD)
[<<] or [>>]
[*]
S1.7
PLU
20
FLAG
Set flag data.(Ex.29)
The Default Flag Data can be set
at SPEC 3 ~ 6 and the Flag data
consists of one or two digits,
which depends on the selected
Barcode type.
[2][9]
[*]
S1.8
PLU
00000
IT CODE
Enter item code.(Ex.20020)
[2][0][0][2][0]
S1.9
PLU
00000
EX CODE
No appended item code of PLU

Other manuals for Digi SM-5100