©2013DigiInternational,Inc. 16
XPress™EthernetBridgeGettingStartedGuide
updates.
1.Verifytheradioisa900MHzunit.(PartNo.:XEB09CIxx)
2.EntertheIPAddressoftheradiointoyourwebbrowsertoconnecttotheWebUI(DefaultIPis
192.168.17.17).Ifnecessary,usetheIPDiscoveryutilitytoscanyournetworkandfindtheIP
addressoftheunit.
3.TheopeningpageofthewebUIshowsthefirmwareversionnumberfortheWebUIandtheradio.
TheWebUIfirmwareversionnumberisfoundatthetopofthewebpagetotheleftofthelogin
box.
TheRadiofirmwareversionnumberisfoundasthelastitemunder"DeviceInformation."
Note:IfyourWebUIfirmwareversionnumberislowerthan1.37.xxxxand/or
yourRadiofirmware versionnumberislowerthan060,pleasecontactDigi
technicalsupporttoupdateyourfirmware.
4.IfyourWebUIfirmwareversionnumberis1.57.xxxx,youwillneedtoupdatetoversion1.6x.xxxx.
5.IfyourRadiofirmwareversionnumberis075,youwillneedtoupdatetoversion08x.
6.IfanupgradeisneededforeithertheWebUIortheRadio,pleasedownloadtheappropriate.zip
folder.Bothfirmwaretypeswillbelocatedwithin.zipfolderontheDigiSupportWebsite.
7.Usingtheradio'swebbrowserinterfaceinstepone,enterthepasswordandclicktheLoginbutton.
(Ifyoudon'tknowthepassword,usetheFinderutilitytoreadorresetit.)
8.Nearthebottomoftheadminpage,thereisasectiontitled"UploadNewFirmware".Enterthe
pathtotheRadioFirmwareUpdatefileendingin.bin,orclicktheBrowsebuttontofindit.
9.Next,clickUploadFirmwareandOKtoconfirm.Afterafewsecondstheradioshouldresetand
returntotheloginpage.
10.RepeatstepeightfortheWebUIfirmwareupdatefilewnsingin.webbin
Bylookingfortheversionnumbersontheloginpageinsteptwo,youcanverifytheupdateshaveloaded
successfully.
Note:Ifyoureceiveanewradiowithversion08xradiofirmware and1.6x.xxxx
WebUIfirmware,andyouwishtointegratethenewradiointoanexistingnet
workthatusesradiofirmwareversion075andWebUIversion1.57.xxxx,you
willneedtoloadtheolderfirmwareontothenewradio.Theyarenotback
wardscompatible.Thestepstorevertfirmwarewillbethesameasupgrading,
exceptyouwillneedtodowngradetheWebUIfirmwarefirst,thendowngrade
theradiofirmware.
FCC Certification
TheXPress™EthernetBridgecomplieswithPart15oftheFCCrulesandregulations.Compliancewith
labelingrequirements,FCCnoticesandantennaregulationsisrequired.
IMPORTANT:TheXPress™EthernetBridgehasbeencertifiedbytheFCCforusewithotherproducts
withoutanyfurthercertification(asperFCCsection2.1091).Changesormodificationsnotexpressly
approvedbyDigiInternationalcouldvoidtheusersauthoritytooperatetheequipment.
IMPORTANT:TheXPress™EthernetBridgehasbeencertifiedforfixedbasestationandmobile
applications.Ifmoduleswillbeusedforportableapplications,thedevicemustundergoSARtesting.