EasyManuals Logo

DigiPos DS-900 User Manual

Default Icon
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
23
Important!
When connecting or disconnecting the power supply from the printer, be sure that the
following cautions are observed.
(1) Use a power supply (Limited Power Supply) of DC 24V±10% and more than 2.5A.
(2) Be careful about installing the printer in an area where there is noise.
(3) Take the appropriate measure to protect against electrostatic AC line noise, etc.
6-5. Environmental Requirements
(1) Operating
Temperature 5°C to 40°C
Humidity 10% to 90% RH (without condensation)
(2) Transport/Storage (except paper)
Temperature -20°C to 60°C
Humidity 10% to 90% RH (without condensation)
6-6. Reliability
(1) MCBF 60 million lines (based on an average printing rate of 12.5% with paper
thickness in the range of from 65µm - 75µm)
35 million lines (based on an average printing rate of 12.5% with paper
thickness in the range of from 76µm - 150µm)
(2) Head Life 100 million pulses, 100Km
(3) Cutter Life 1.0 million cuttings (if the paper thickness is between 65 and 90µm)
6-7. Certification
(1) FCC PART15 CLASS A
(2) UL/cUL (UL 60950-1)
(3) MIC
(4) CE-EMCD (CE-EMCD Class B should use Parallel shield Cable complied with IEEE-1284 standards)
(5) RoHS (TUV)
(6) CCC

Other manuals for DigiPos DS-900

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DigiPos DS-900 and is the answer not in the manual?

DigiPos DS-900 Specifications

General IconGeneral
BrandDigiPos
ModelDS-900
CategoryPrinter
LanguageEnglish

Related product manuals