EN-11
Menu Structure 8.2
English

  
Displays the temperature of heating circuit 3 measured on the
sensor. This temperature is the controlled variable for heating
circuit 3.
Heating circuit 3
heating operation


Indicates if a request for heating has been made. Even if there is a
request present, it is possible that the heat pump will not operate
(e.g. because of the utility company shut-off time).
“Heating system flushing” is displayed when the system is being
flushed.
A HP block combined with a sufficiently high cylinder temperature
is indicated by “Bivalent-renewable”.
At least 1 heating
circuit
 
Indicates which heat generator is available to carry out the heating
request
1: max. 1 compressor, 2: max. 2 compressors, 3: max. 2
compressors and a 2nd heat generator
Heating operation
  
Sensor for determining the defrost end with hot gas defrosting Air HP with hot
gas defrosting
 

Displays the temperature measured in the cylinder in bivalent-
renewable systems
Bivalent -
renewable
 
 
Displays the measured return flow temperature during cooling
operation measured at the heat exchanger input
Passive cooling
function
cooling operation
 
 
Displays the measured flow temperature during cooling operation
measured at the heat exchanger output
Cooling function
passive
 

Displays the temperature measured on the “Antifreeze Cool”
sensor.
This temperature is used to safeguard the operating limits in
cooling operation.
Reversible HP
cooling operation
  
Displays the temperature measured by the hot gas sensor Reversible HP
  
 
Displays the current room set temperature with silent cooling. Cooling function
silent cooling
cooling operation
  
Displays the temperature measured in the room in which room
climate control station 1 is installed.
This temperature is the controlled variable for silent cooling.
Cooling function
silent cooling
or
room regulation
  
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
silent cooling
  
Displays the temperature measured in the room in which room
climate control station 2 is installed.
This value is used for calculating the dew point with silent cooling.
Cooling function
silent cooling
2 room stations
  
Displays the current humidity in the room in which room climate
control station 2 is installed. This value is used for calculating the
dew point with silent cooling.
Cooling function
silent cooling
2 room stations


Indicates if a request for cooling has been made Cooling function
cooling operation
  
 
Displays the current domestic hot water set temperature Hot water
sensors
  

Displays the measured domestic hot water temperature. This
temperature is the controlled variable for DHW preparation.
Hot water
sensor
  Display of sensor and system values Display