Service - 76 SK600 Operator’s Manual
Procedures
Track Tension
Check before startup and every 10 hours. Adjust as needed.
Check
1. Remove cover.
2. With tube and tab (top): Measure distance
(A) from end of viewing window to front end
of spring guide. Tension is correct when
measurement is 5/8-3/4” (16-19mm).
With mark on tube (bottom): Ensure mark on
tube (2) is aligned with cutout (1) in plate.
3. Install cover.
Adjust
1. Remove cover.
2. With tube and tab (top): Measure distance
(A) from end of viewing window to front end
of spring guide (orange tab). Tension is
correct when measurement is 5/8-3/4”
(16-19mm).
With mark on tube (bottom): Ensure mark on
tube (2) is aligned with cutout (1) in plate.
3. Turn bolt (shown) clockwise to tighten and
counterclockwise to loosen as needed.
4. Install cover.
t51om025w.eps
1
2