SK650 Operator’s Manual Transport - 47
Tow
CMW
Prepare Unit for Towing
1. Block tracks.
2. Engage parking brake (shown).
3. Loosen locknut and loosen bypass valves (shown)
three turns.
Return Unit to Normal Operation
1. Tighten bypass valves and torque locknut to 12.5 ft•lb (17 N•m).
2. Disengage parking brake.
3. Unblock tracks.
IMPORTANT: Open bypass valves in both
front and rear pumps.
IMPORTANT: Close bypass valve in both front and rear pumps.