EasyManua.ls Logo

DITEC 192C - User Manual

DITEC 192C
26 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DITEC S.p.A.
Via Mons. Banfi, 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - ditec@ditecva.com
192C
IP1836
rev. 2005-08-23
I
Manuale di installazione quadro elettronico per automazione REX
Electric board installation handbook for REX automations
Notice d’installation armoire électrique pour automatisme REX
Installationsanleitung für Türsteuerung REX
Manual de instalación del tablero eléctrico para automación REX
Manual de instalação quadro eléctrico para automação REX
GB
F
D
E
P
Fig. 1
MOT
BL
OPEN
RP
DIP
R1
RESET
27
9
8
3
2
1
1
0
TC
on
off
3 41 2
POWER
ALARM
+
-
+
-
~
~
24 V
BAT
ENC
-
-
+
+
Motor
L
N
230 V~
Transf.
Fuse 1A
Lock
Fuse
F10A
192C
1CELA
12 V
12 V
P1 SP P2 R1 SR R2
1
2
Rosso - Red
Bianco - White
10
+ -
COM
N.O.
N.C.
24 V= / 0,3 A (max
)
Chiusura automatica / Automatic closure; Chiude / Closing
Apre / Opening
Sicurezza di inversione / Reversal safety contact
Stop
Apertura parziale / Partial openin
g
MIN MAX
R1
Spinta sugli ostacoli
Thrust on obstacles
0% 100%
TC
Tempo chiusura automatica
Automatic closure time
0 s 30 s
RP
Apertura parziale
Partial opening
5% 90%
OFF ON
DIP1
Funzionamento blocco
Lock functioning
Non alimentato
Unpowered
Alimentato
Powered
DIP2
Senso di marcia
Movement direction
1 anta dx/2 ante
1 wing rt/2 wings
1 anta sx
1 wing left
DIP3
Funzionamento batterie
Batteries function
Antipanico
Antipanic
Continuo
Close
DIP4
Ultima manovra con
batterie scariche
Last operation with
unloaded batteries
Chiusura
Closing
Apertura
Opening

Questions and Answers

  • L
    Lori ChavezAug 4, 2025
    Why DITEC Control Unit door doesn’t open or close?
    • T
      Teresa ReillyAug 5, 2025
      If your DITEC Control Unit door isn’t opening or closing, there are several potential causes: * **Power Issues:** Ensure the electrical panel is receiving power by checking if the POWER ALARM LED is steadily lit. * **Short Circuit:** Disconnect all accessories from terminals 0-1 (24 V= must be present) and reconnect them one at a time to identify any short circuits. * **Blown Fuse:** Replace the fuse on the transformer. * **Safety Contacts:** Verify terminals 8 and 9 on the electrical panel, as well as the position of the function selector (if equipped), to ensure safety contacts are properly closed. * **Mechanical Obstruction:** Confirm that the door wings can move freely, as bolts and locks may be obstructing movement.
  • R
    Robert WoodsAug 10, 2025
    What to do if DITEC Control Unit door opens but doesn’t close?
    • C
      Chelsea OrtizAug 10, 2025
      If your DITEC Control Unit door opens but fails to close, consider the following possibilities: * **Safety Contacts:** Check terminal 8 on the electrical panel to ensure safety contacts are properly configured. * **Photocells:** Inspect the photocells to make sure they are clean and functioning correctly. * **Radar Interference:** Ensure the radar is free from vibrations, false detections, or any moving objects within its detection range. * **Automatic Close Function:** Verify jumper 1-2 and the position of the function selector (if present) to confirm the automatic close function is enabled.
  • H
    Hannah HodgesAug 16, 2025
    Why DITEC Control Unit door opens by itself?
    • C
      Cheryl BrownAug 16, 2025
      If your DITEC Control Unit door is opening by itself, the issue might be related to: * **Radar Instability:** Check if the radar is experiencing vibrations, false detections, or detecting moving objects. Ensure that the radar's environment is stable and free from interference.
  • A
    Amanda RossAug 22, 2025
    What to do if DITEC Control Unit door opens a short distance and then stops?
    • R
      Rachel YoungAug 22, 2025
      If your DITEC Control Unit door opens or closes only a short distance before stopping, here’s what to check: * **Encoder Issues:** If the POWER ALARM LED is flashing, the encoder might be broken and needs replacement. * **Mechanical Friction:** Manually check that the door wings move freely. Adjust the wing height by lifting it to reduce any friction.
  • G
    Gary OrtegaAug 27, 2025
    How to fix DITEC Control Unit external safeties that don’t trip?
    • M
      Mrs. Sierra RobinsonAug 27, 2025
      If the external safeties on your DITEC Control Unit aren’t tripping, it could be due to: * **Incorrect Wiring:** Ensure that the N.C. safety contacts are connected in series and that any unnecessary jumpers have been removed.

Summary

General Safety Precautions

Technical Data

Electrical Connections

Controls

Details on the control inputs for automation functions like closing and safety.

Output and Accessories

Information on power outputs for accessories and battery backup systems.

Adjustment Trimmer

Configuration of trimmers for obstacle thrust, auto-closure time, and partial opening.

Selection Dip Switch

Configuration options using DIP switches for locking, direction, and battery modes.

Indicators

Description of LED indicators for power status and potential faults.

Start Up

Trouble Shooting

Example of Application Without Selector

Example of Application With ComH-ComK Selector

DITEC 192C Specifications

General IconGeneral
BrandDITEC
Model192C
CategoryControl Unit
LanguageEnglish