Thank you for the purchase of this DiversiTech condensate pump. This
pump is designed to automatically remove the condensate water that
collects from appliances such as air conditioners and de-humidiers.
The pump has a built-in tank that collects the water from the appliance.
When the water collected reaches sucient level inside the pump tank,
the pump switches on and pumps the water to a remote location for
disposal. When the tank is suciently empty the pump automatically
switches o.
The pump is capable of liing water to its rated height and is equipped
with a check valve that prevents water from owing back into the tank
when the pump shuts o.
The pump is also equipped with a switch that activates when the water in
the tank reaches an overow condition. The overow safety switch may
be connected to turn o the appliance if the high water condition occurs.
Pump should be stored indoors.
The chosen location should be clean and dry.
Carefully open the carton to avoid damage to the pump. Do not use a
knife or other sharp object that may scratch the pump’s cover. Aer
opening the carton, look for damage. If damage is found le a claim with
the freight carrier.
Connect power cord to a supply voltage and frequency that matches
what is shown on the pump nameplate. Source voltages lower than the
rated supply can reduce performance and cause the pump to overheat.
The pump must be level and should be placed on a solid surface or oor.
The pump has rubber feet to reduce noise and keep it in place during
operation.
Do not use this pump in the presence of spraying or standing water,
it may cause a shock. This pump is not suitable for use in Class I or Class II
locations (explosive gas or dust).
Do not cover the pump air vents. The pump is air cooled. Do not cover
the vent holes located on the top or sides of the pump housing. The pump
may be operated continuously as long as the air vents are not covered.
The condensate pump is equipped with optional mounting tabs which allow
the tank to be screwed to a wall or equipment side panel. The
screw-to-screw distance is 10-1/16”. When mounting into drywall or
concrete walls the screws must have anchors which provide the necessary
support in the wall material.
General Information
Unpacking
Power Source
Pump Installation
CHECK FOR
SHIPMENT
DAMAGE
Mounting