QuickStart
FlexxPump 125 time
5.3 Actions with the activation and programming key (APK)
1. Remove the APK from the underside of the
FlexxPump 125 time.
2. Place the APK on the action area on the
front of the FlexxPump 125 time
3. Remove the APK from the action area (SET)
as long as the desired menu item is displayed in
the LCD.
5.4 SET menu
The SET menu allows you to change the operating mode and the cartridge
size of the FlexxPump 125 time. You can switch between hour mode -h- and
empty time mode Et.
5.5 PRO menu
Being in operating mode hour mode -h-, you can change the break time h as
well as the number of cycles c (number of strokes). Being in PRO menu the
rst step is to set the break time h and after-wards the number of cycles c;
direct access to the number of cycles c is not possible.
Running empty time mode Et, you can change the emptying time Et in
months.
5.6 FIL menu
This function enables you to prell connected accessories (tubes, distri-
butors,...) with the lubricant contained in the lubricant cartridge, especi-ally
during the initial start-up of the FlexxPump 125 time. However, the process
can also be aborted manually at any time.
5.7 Input and output signals - time control
PIN assignment - time control
PIN Assignment Colour
1 +24 V DC brown
2 unallocated white
3 ground blue
4 output signal black
Type: M12x1 female connector; 4-pin; A-coded
The FlexxPump 125 time can be switched off completely by switching off the
supply voltage.
The output signal at PIN 4 can be tapped for further processing (e.g.
indicator light or external control). The maximum permissible current
output must not exceed Imax < 20mA. No inductive load (e.g. relay) may be
connected!
LCD Description Output signal (PIN 4)
OFF switched off low, permanent
ON ready for operation high, permanent
E1 cartridge empty 0,5Hz square wave signal, permanent
E1 cartridge error low, permanent
E2 overload low, permanent
E3 undervoltage low, permanent
E4 fatal error low, permanent
6. Maintenance
NOTICE
A used lubricant cartridge must not be replaced on the FlexxPump 125 time
as the integrated stroke counter of the FlexxPump 125 time is automatically
reset by the cartridge sensor after a cartridge has been removed. Only use
full lubricant cartridges.
3
2
1
4
-h- Operating mode: hour mode -h-
Et Operating mode: empty time mode Et
125/250 Changeable value of cartridge size
If you would like to change the operating mode, move the activation and
programming key back to the action area.
When your desired operating mode is displayed on the LCD, remove the
activation and programming key from the action area.
RUN RUN-menu
01...50 During the manually triggered active RUN command („quick check“/
extra dispense), the LCD displays the approximate back pressure in
bar. In addition, the green LED lights up.
PRO PRO-menu
h1...240 Adjustable setting of break time h
c1...10 Adjustbale setting of number of strokes c
01...24 Adjustabe setting of emptying time Et
FIL FIL-menu
01...50 During the manually triggered, active FIL command, the LCD displays
the approximate back pressure in bar. In addition, the green LED
lights up.
Clr If the process is aborted during FIL command Clr appears at rst.
Additional character on the LCD
Displayed when the cartridge is empty and needs to be replaced.
MAX After each cycle the maximum back pressure is displayed in bar.