Parameter Description Navigation Values
Default
Value
Parameter Description Navigation Values
Default
Value
Positioning
system
Type of positioning system: with Encoder or
traditional. Note: Can only be modified in Temporary
Oper. mode
◄► (Selection)
Encoder
Clockwise;
Encoder
Counter
clockwise
Encoder
Clockwise
Autosetting
Start of floor position self-learning procedure. Can
only be modified in Temporary Operation mode.
◄► (Selection)
No;
Yes
No
Floor
Position
Position value for each floor
▲▼
(Increase/Decrease)
◄► (Selection)
Accel.
Time
Acceleration time. Time required to switch from start
speed to travelling speed.
▲▼
(Increase/Decrease)
1,0 s <->
5,0 s
3,0 s
Starting
Boost
Starting speed
▲▼
(Increase/Decrease)
0 s <-> 10
s
3 %
Stopping
Boost
Final (stopping) speed
▲▼
(Increase/Decrease)
0 s <-> 10
s
4 %
Max speed Maximum speed during the travel
▲▼
(Increase/Decrease)
5 s <->
100 s
100 %
Inspection
speed
Travelling speed in inspection mode
▲▼
(Increase/Decrease)
5 s <->
100 s
50 %
AGB/AGH
speed
Travelling speed on AGB/AGH limit points. Same
speed adopted during emergency operations
▲▼
(Increase/Decrease)
1 s <-> 15
s
10 %
Delay Dir.-
BRK
VVVF: Delay between activation of travel direction
and BRK command (start)
▲▼
(Increase/Decrease)
0,0 s <->
3,0 s
0,5 s -
VVVF
0,0 s -
Others
OLEO: Star / Delta delay
▲▼
(Increase/Decrease)
0,0 s <->
3,0 s
0,5 s –
VVVF
0,5 s –
Star/Delta
0,0 s -
Others
Delay
BRK-S
Delay between activation of BRK command and
beginning of the analogic speed ramp
▲▼
(Increase/Decrease)
0,0 s <->
3,0 s
0,3 s -
VVVF
0,0 s -
Others
Delay
BRK-Dir.
Delay between deactivation of run command and
deactivation of travelling direction (stop at floor)
▲▼
(Increase/Decrease)
0,0 s <->
3,0 s
1,5 s -
VVVF
0,0 s -
Others
Emergency
BRK On
Emergency break modulation parameter
▲▼
(Increase/Decrease)
0,0 s <->
5,0 s
0,0s
Emergency
BRK Off
Emergency break modulation parameter
▲▼
(Increase/Decrease)
0,0 s <->
5,0 s
0,0s