6
LIST OF MAIN PART
1. Chuck
2. LED work light
3. On-off switch
4. Battery indicator
5. Forward/ reverse rotation switch
TECHNICAL SPECIFIATIONS
Power
12 V
Speed
0-2700/min
Max. Torque
120Nm
Chuck size
3/8
Noise
Sound pressure level
73,2 dB(A) K=3 dB(A)
Sound power level
84,2 dB(A) K=3 dB(A)
Vibration level a
h,D
0,571 m/s² k= 1,5 m/s²
NOISE/VIBRATION INFORMATION
Measured sound values determined according to EN 62841.
Wear hearing protection!
Vibration total values (triax vector sum) determined according to EN 62841:
The vibration emission level given in this information sheet has been measured in
accordance with a standardized test given in EN 62841 and may be used to compare
one tool with another.
It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool.
However if the tool is used for different applications, with different accessories or
poorly maintained, the vibration emission may differ. This may significantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the
times when the tool is switched off or when it is running but not actually doing the job.
This may significantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of
vibration such as: maintain the tool and the accessories, keep the hands warm,
organisation of work patterns.
Vibration risk limitation suggestions:
1) Wear glove during operation