C-6000i Computerized Jigging Reel User Manual
7
The two communication wires are connected to terminal blocks in the
connection box. The brown wire connects to one terminal block and the blue
one to another. For illustration see supplied connection diagram.
Note: A polarity reversal will not harm the reel in any way but it will
result in an operational failure of the machine while incorrectly
connected. If nothing happens on the screen when power is applied, check
the polarity of the connection.
Switching the Power On
When the machine has been mounted and connected to the electric system,
the power can be applied by the switch on the circuit breaker (or an optional
switch). The machine takes a few seconds to perform a power on self-test
and then displays the program version and serial number for 2 seconds. Then
the main screen (screen 1) will appear on the display. It is necessary to turn
the drum as much as one turn to initialize. Then the machine enters Stop state
and the drum can no longer be turned freely.
Note: Each time power is applied the reel won’t work if not initialized by
turning the drum. This will, however, happen automatically when the
sinker is thrown overboard.
High and Low Voltage
If the voltage of the electrical system rises above approximately 32V the
overload voltage protection unit in the connection box will short-circuit the
output of the circuit breaker which then disconnects the reel from the
electrical system. If on the other hand, the voltage is too low (below 10V on
a 12V system and below 20V on a 24V system) the machine will flash the
value of the voltage measurement on the display and emit a sound as a
warning. If the voltage continues to drop, it will finally result in an
operational failure of the reel. This will however, not harm the machine in
any way but it can harm the batteries of the electrical system.
Line and Sinker